Power manager Integration Utility - When this utility is run, the error message "Export complete with errors. Please check logs for details" is seen
Cause
Running the Power Manager Integration utility with Windows user account instead of Administrator account

Log:
2016-10-12 15:09:33 - ERROR: System.Security.SecurityException: Requested
registry access is not allowed.
at System.ThrowHelper.ThrowSecurityException(ExceptionResource resource)
at Microsoft.Win32.RegistryKey.OpenSubKey(String name, Boolean writable)
at
IntegrationUtility.Services.ProductRegistry.GetProductRegistryValue(String
subkey, String valueName)
The Zone of the assembly that failed was:
MyComputer
2016-10-12 15:10:19 - ERROR: Error enabling EWS: Exception is:
System.InvalidOperationException: Failed to map the path '/ews'.
at System.Web.Configuration.ProcessHostConfigUtils.MapPathActual(String
siteName, VirtualPath path)
at System.Web.Configuration.ProcessHostMapPath.MapPathCaching(String
siteID, VirtualPath path)
at
System.Web.Configuration.ProcessHostMapPath.System.Web.Configuration.IConfigMapPath2.MapPath(String
siteID, VirtualPath path)
at
System.Web.Configuration.WebConfigurationHost.InitForConfiguration(String&
locationSubPath, String& configPath, String& locationConfigPath,
IInternalConfigRoot configRoot, Object[] hostInitConfigurationParams)
at System.Configuration.Configuration..ctor(String locationSubPath, Type
typeConfigHost, Object[] hostInitConfigurationParams)
at
System.Configuration.Internal.InternalConfigConfigurationFactory.System.Configuration.Internal.IInternalConfigConfigurationFactory.Create(Type
typeConfigHost, Object[] hostInitConfigurationParams)
at
System.Web.Configuration.WebConfigurationHost.OpenConfiguration(WebLevel
webLevel, ConfigurationFileMap fileMap, VirtualPath path, String site,
String locationSubPath, String server, String userName, String password,
IntPtr tokenHandle)
at
IntegrationUtility.Services.ConfigurationProcessor.SetWebConfigurationValue(String
virtualPath, String key, String value)
at IntegrationUtility.Services.ConfigurationProcessor.EnableEws().
2016-10-12 15:10:19 - ERROR: Error enabling token service: Exception is:
System.InvalidOperationException: Failed to map the path
'/systemdataservice'.
at System.Web.Configuration.ProcessHostConfigUtils.MapPathActual(String
siteName, VirtualPath path)
at System.Web.Configuration.ProcessHostMapPath.MapPathCaching(String
siteID, VirtualPath path)
at
System.Web.Configuration.ProcessHostMapPath.System.Web.Configuration.IConfigMapPath2.MapPath(String
siteID, VirtualPath path)
at
System.Web.Configuration.WebConfigurationHost.InitForConfiguration(String&
locationSubPath, String& configPath, String& locationConfigPath,
IInternalConfigRoot configRoot, Object[] hostInitConfigurationParams)
at System.Configuration.Configuration..ctor(String locationSubPath, Type
typeConfigHost, Object[] hostInitConfigurationParams)
at
System.Configuration.Internal.InternalConfigConfigurationFactory.System.Configuration.Internal.IInternalConfigConfigurationFactory.Create(Type
typeConfigHost, Object[] hostInitConfigurationParams)
at
System.Web.Configuration.WebConfigurationHost.OpenConfiguration(WebLevel
webLevel, ConfigurationFileMap fileMap, VirtualPath path, String site,
String locationSubPath, String server, String userName, String password,
IntPtr tokenHandle)
at
IntegrationUtility.Services.ConfigurationProcessor.SetWebConfigurationValue(String
virtualPath, String key, String value)
at
IntegrationUtility.Services.ConfigurationProcessor.EnableTokenService().

Resolution:
Run the tool with Administrator permissions.

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군
  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings