What are the heassink fan replacement part numbers for the ATV630, ATV930 and ATV660 Altivar Process Drives?

Resolution:

Open Style Products (Altivar 630/930 and Altivar 650/950)

img1


Enclosed Drive Systems (Altivar 660/960 and Altivar 680/980)
Fan Part Numbers & Quantity:

  • Size 1
    • 110kW - 160kW (125hp - 200hp)
    • Need 1 of each
      • VX5VPM001 - Fan Kit, Connection Cables
      • VX5VPM003 - Enclosure Door Fan
  • Size 2
    • 200kW - 315kW (250hp - 500hp)
    • Need 2 of each
      • VX5VPM001 - Fan Kit, Connection Cables
    • Need 1
      • VX5VPM003 - Enclosure Door Fan
  • Size 3
    • 400kW - 500kW (500hp - 600hp)
    • Need 3 of each
      • VX5VPM001 - Fan Kit, Connection Cables
    • Need 1
      • VX5VPM003 - Enclosure Door Fan
  • Size 4
    • 630kW (700hp)
    • Need 4 of each
      • VX5VPM001 - Fan Kit, Connection Cables
    • Need 1
      • VX5VPM003 - Enclosure Door Fan

Enclosed Drive Systems below size 110kW use the open style drives in the enclosure so for the fan part numbers use the table above.
For Example - ATV660D30T4N..... uses the ATV630D30N4 power converter so use the VX5VPS4001 for the fan part number.

Other Part Numbers for Enclosed Drive Systems to consider getting if replacing the fans maybe...

  • VX5XPM002 - DC-Supply for Fan
  • VX4XPMC1180N4 - Fan Supply Board
    • Quantity maybe different based on frame size. Drive will require 1 more fan supply board than the quantity of fan kits needed.

If this article does not answer your question, check out our FAQ database that has answers to more commonly asked questions:

Frequently Asked Questions - Schneider Electric (se.com)

If this FAQ did not solve your issue, you can call us at 1-888-778-2733 Option 2 and then 4 or e-mail us at drive.products.support@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)

슈나이더 일렉트릭 Korea

첨부 파일
ATV630_IS_Fan_Size_1-2-3_EAV64373_02.pdf [4.99 MB]
자세히 알아보기
제품군
자세히 알아보기
제품군

도움이 필요하신가요?

도움이 필요하신가요?

제품 선택기

제품 선택기

애플리케이션에 적합한 제품과 액세서리를 빠르고 쉽게 찾을 수 있습니다.

견적 받기

견적 받기

영업 관련하여 온라인으로 문의하시면 전문가가 연락드립니다.

구매처

구매처

해당 지역의 가장 가까운 슈나이더 일렉트릭 대리점을 쉽게 찾을 수 있습니다.

지원 센터

지원 센터

한 곳에서 모든 요구 사항에 대한 지원 리소스를 찾아보십시오.

  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings