What are the Battery Part Numbers used by Schneider Automation Legacy PRODUCTS?
The following are the battery part numbers, by product family, for Schneider PLC's. Date: April 8, 2005
Obsolete Battery Part Numbers are
| Product Line | Model | Type | Part Number | Manufacturer |
| Quantum | ||||
| 140CPUxx | Lithium 3V | 990XCP98000 | Duracell (DL2/3A) (soldered connector) | |
| 140XCP90000 | Lithium | 990XCP99000 | ||
| Sercos Controller | 141MMS42501 | Lithium 3V | 990XCP98000 or 043502625 | Duracell (DL2/3A) (soldered connector) |
| Sercos Controller | 141MMS53502 | Lithium 3V | 990XCP98000 or 043502625 | Duracell (DL2/3A) (soldered connector) |
| Compact | ||||
| PC-O984-xx | Lithium 3.6V (long) "O" | 60-0576-000 | Eternacell (T04/41) | |
| PC-A984-1xx PC-E984-2xx | Lithium 3.6V (short) "A" | 60-0576-100 | Saft (LS3) Maxell (ER3STC) | |
| Momentum | ||||
| Option Adapters | 172xNN2xx2 PNN PV:03 JNN PV:01 | Lithium 3.6V | 170XTS15000 | Tadiran (TL-5955) |
| Option Adapters | 172xNN2xx2 | Alkaline "AAA" | Commercially Available | |
| Modicon Micro | ||||
| 110CPUx1x0x | Lithium Capacitor | 110XCP98000 110XCP99000 | Duracel (DL2/3A) (soldered connector) | |
| Modicon 984 | ||||
| Co-Pro Co-Pro 984A 984B | AM-C986-003 AM-C986-004 AM-M907-1xx AM-M909-0xx | (2 cell pack) | MA-9255-000 | |
| C921 (TOD Clock) | AM-C921-xx | 60-0490-000 | ||
| 984L 984O 984E 984O 984O Co-Pro Co-Pro M984 B984 | PC-L984-x8x PC-O984-x8x PC-E984-x8x PC-O984-455 PC-O984-351 AM-C986-004 AM-C996-80x PC-M984-23x AS-B984-1xx | Lithium 3.6V "AA" | 60-0515-000 | Eternacell (T06141) Maxell (ERGC#5) Saft (LS6) Tadaran (TL-5104) |
| S929 ASCII/BASIC | AM-S929-00x AS-B885-00x | Lithium | MA-8234-000 | |
| AM-O984-ATX | 60-0490-000 | |||
| 3220 Motion Controller | Rechargeable (Qty. 2) | 60-0610-000 | ||
| 3240 Motion Controller | 100-865 | (Qty. 3) | 60-0595-000 | |
| AM-O984-MCX | | |||
| Modicon 884 | ||||
| AS-884A-xx AS-J890-x0x | MA-8234-000 | |||
| Modicon 584 | ||||
| 506P 509P | AS-506P-xx AS-509P-xx | Lithium (3 card) Lithium (4 card) | MA-0147-001 MA-0147-002 | |
| M507 | AS-M507-00x | 60-0481-000 | ||
| 3 Card Battery Pack | Lithium Alkaline | AS-5284-001 AS-5284-002 | ||
| 4 Card Battery Pack | Lithium Alkaline | AS-5378-002 | ||
| Modicon 484 | ||||
| Lithium Alkaline | MA-0147-001 60-0286-000 | |||
| Modbus Multiplexer | ||||
| NW-0278-000 | | |||
| 0085/0185 (Sharp) | ||||
| (with connector) (without connector) | PA-0493-000 | Sharp (UBATN-5001-SCZZ) | ||
| Symax | ||||
| Model 400 Model 450 Model 600 Model 650 PS25 PS35 8052 MCM713 | Lithium 3.6V "AA" | 60-0515-000 29576-03688 (SqD Part #) | Eternacell (T06141) Maxell (ERGC#5) Saft (LS6) Tadaran (TL-5104) | |
| PS20/21 PS30/31 PS50/51 PS60/61 | Alkaline "D" | Commercially Available | ||
| 8005 Model 50 | Ram Memory Pack | 8005 MP1 8005 MP4 | ||
| PS20 | Battery Holder | 29904-08200 (SqD Part#) | ||
| SCP1xx 8040 PCM-110 | 8020 SMM115 (SqD Part #) | |||
| M100 | 29904-08960 (SqD Part #) | |||
| 8009 Compact | Lithium 3V (Type BA1) | Sanyo (CR12600SE) TDI Battery Co. (?) Otte Controls (DUNT-521NCZZ) | ||
| Symax 20 | 8884 SBP20 (SqD Part #) | |||
| PanelMate | ||||
| all models | 60-0628-000 | Maxell | ||
| 3240 | PM0632400 | (Qty. 3) | 60-0595-000 | |
| FM1100 | PA-0285-000 | |||
| 2184 | MA-024M-000 | |||
| Telemecanique | ||||
| TSX Premium TSX Micro | TSXP57xx TSXP37xx | Lithium 3.6V "1/2 AA" Single Ten Pack | TSXPLP01 TSXPLP101 | Saft (LS3) Maxell (ER3STC) |
| PCMCIA RAM | TSXMRPxx | Lithium 3V "Button" Single 10 Pack | TSXBATM01 | Panasonic (BR2325) |
| CCX17 | TCCX17xx | Lithium 3.6V "1/2 AA" Single Ten Pack | TSXPLP01 TSXPLP101 | Saft (LS3) Maxell (ER3STC) |
| FTX117 | TFTXRSMxx | Lithium 3V "Button" Single 10 Pack | TSXBATM01 TSXBATM101 | Panasonic (BR2325) |
| TSX 17 | Lithium 3.6V "1/2 AA" | TSX17ACC1 | Saft (LS3) Maxell (ER3STC) (Soldered Connectors) | |
| XBTKN XBTKM | Lithium 3.6V "1/2 AA" | TSX17ACC1 | Saft (LS3) Maxell (ER3STC) (Soldered Connectors) | |
| Series 7 | ||||
| TSX 27xx TSX P471x/P472x TSX RAM xx 8 TSX AXM 162 TSX AXM 171xx/182 TSX SCM 2xx UC TSX 27 | 2.6 V | | 2.4 Volt with minimum of 110 mAH Shrink-wrapped cells Soldered on board | |
| TSX P473xx/P474xx TSX P67xx TSX 76 x TSX P871/P872/P874xx TSX P76 x TSX P107xx TPMX P474xx TPMX P674xx TPMX874xx TPMX P1074xx TSX T407 x TSX RAM xx 16 TSX MEM 4x TSX P87 30/310 | 3.6V 3.6V (Qty. 3) | | 3.6 Volt with minimum of 110 mAH Shrink-wrapped cells Soldered on board |