Ecostruxure Process Expert: Antivirus recommendations to use in System Server machine.
Answer/Solution:
You can use any Antivirus, there is no recommendations from Schneider for antivirus software to use in conjunction with EPE software. But you should ensure that all the ports used by EPE should be allowed by antivirus software firewall that you are using.EPE software calls different software components and services to work collaboratively. Meantime communication and data exchange will happen between License Manager and Floating License Manager, between System Server and Engineering Client, between Cache database and embedded VM, etc. For all these communications TCP ports are used.
Normally Antivirus comes with firewall, which will block/allow the ports based on the firewall settings. So we need to open and allow the access of these below listed ports by tuning the settings in switches and firewalls.
1. Ports for Server Licensing
| Port | Protocol | Usage / Description |
| 8090 | TCP | Web portal of the FLEXnet License Administrator |
| 27000 | TCP | Communication port from License Manager to Floating License Server in PES V4.2 and earlier version |
| 27010 | TCP | Communication port from License Manager to Floating License Server in PES V4.2 SP1 and above |
| Port | Protocol | Usage / Description |
| 9949 | TCP | Critical messaging port |
| 9950 | TCP | Client / server connection |
| 9951 | TCP | File transfer port between Process Expert components |
| Port | Protocol | Usage / Description |
| 39081 | TCP | Virtual Machine Communication Ports, will also use 39082 and next for next vm instances |
| 39181 | TCP | Virtual Machine Communication Ports, will also use 39182 and next for next vm instances |
| Port | Protocol | Usage / Description |
| 18080 | UDP | Logging / display |
| 18081 | UDP | Logging |
The above information is valid for EPE2020R2 and all its lower versions.