How to generate SQL database detail Disk Usage report?
Issue
How to generate SQL database detail Disk Usage report?

Product Line
Power Monitoring Expert 8.2
Power Monitoring Expert 9.0+
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023


Environment
SQL server databases

Resolution
Display data and log space information for a database

** Warning:  Only those familiar with SQL server and PME should be working with SQL Management Studio.  Making direct modifications to the PME databases can leave a system inoperable and require restoration from back ups. **

1)  Log in to SQL Management Studio
2)  Expand the databases folder, right click ION_Data, select Reports < Standard Reports <  'Disk Usage'
SSMS Disk Usage

3)  To export the report, right click anywhere on the report and select Export and select Excel, PDF or Word

SSMS Disk Usage Report