브랜드

Impact-Company-Logo-English Black-01-177x54

슈나이더 일렉트릭 코리아 웹사이트에 방문해 주셔서 감사합니다.

슈나이더 일렉트릭 코리아 웹사이트 방문자 분들 모두 환영합니다.
		
오늘 무엇을 도와드릴까요?
Data Center Expert | Complete Upgrade Process
Issue:
Complete process for upgrading StruxureWare Data Center Expert

Product Line:
StruxureWare Data Center Expert (DCE)
- Basic Appliance (AP9465)
- Standard Appliance (AP9470)
- Enterprise Appliance (AP9475)
- Virtual Appliance (AP94VMACT)

Environment:
StruxureWare Data Center Expert (all versions)

Resolution:

1) Check your account on the EcoStruxure Entitlements Portal for self-service access to upgrade files. If you're unable to locate and download your necessary files, contact local technical support to verify and associate your support agreement to your entitlements portal account.  You may need to obtain multiple files as Data Center Expert requires incremental upgrades.

2) Download the upgrade.zip files for each upgrade and verify the checksum of the upgrade zip files using a checksum validator of your choice.  Depending on the version, an MD5 or SHA1 checksum will be provided for comparison on the download pages that technical support provided to you.  Steps to verify the checksum can be found in knowledge base FA309128.

3) If your DCE appliance is running as a virtual machine, please ensure that there is more than one hard disk on the virtual appliance.  The bundled storage volume should never be expanded.  A second virtual disk should be added to prevent the appliance from running out of storage during the upgrade process.  Complete instructions on adding an additional hard disk can be found within knowledge base FA309639.

4) Ensure that you have a valid backup of your DCE appliance.  Instructions on backing up to a Windows Share can be found in knowledge base FA299440.
NOTE: Backups can only be restored on the same version they are created on.  If performing multiple upgrades, it is recommended to create backups after each upgrade.

5) Issue the upgrade to DCE following the instructions in knowledge base FA158311.

6) Repeat steps 2, 4, and 5 for the remaining upgrades required to come up to version 7.8.1.

7) Upgrading to version 7.9.0 requires a reinstallation of software and restoring from backup due to an operating system change from CentOS to Rocky Linux. The 7.9.0 ISO and OVA files are accessible through the entitlements portal.  Detailed instructions on upgrading to 7.9.0 can be found on our Help Center at: https://dcimsupport.ecostruxureit.com/hc/en-us/articles/4408917042577-Complete-upgrade-process-for-DCE-7-9-0

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군

도움이 필요하신가요?

  • 제품 선택기

    애플리케이션에 적합한 제품과 액세서리를 빠르고 쉽게 찾을 수 있습니다.

  • 견적 받기

    영업 관련하여 온라인으로 문의하시면 전문가가 연락드립니다.

  • 구매처

    해당 지역의 가장 가까운 슈나이더 일렉트릭 대리점을 쉽게 찾을 수 있습니다.

  • 지원 센터

    한 곳에서 모든 요구 사항에 대한 지원 리소스를 찾아보십시오.

  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings