Why, sometimes the HMIBMI start in UEFI mode?

Due to CPU issues, sometime the eMMC is not recognized during the starting and the HMIBMI start in EFII mode

The FAQ is applicable for HMIBMI with a BIOS version lower than V115

To fix the booting issue, need to upgrade the BIOS, the latest version is V117

Here the procedure to upgrade the BIOS version
1/ Download the following file => V117


2/ Unzip and copy all files to the root of USB flash disk (the USB flash disk must be in FAT32)
copy all file to usb

3/ Insert the USB stick into the USB port and press "F7" during the boot to select the USB disk for boot, select UEFI: Build-in EFI Shell
select boot device

4/ In the Shell mode, you can see your USB stick as fs1, where the BIOS is stored.
Shell mode


5/ enter "fs1:" to select the USB stick
6/ enter "f.nsh B1210000I60X026.bin"
update bin file

The warning message is normal. Press "Y" to install the new BIOS
After installation, you can restart the iPC.
To check if the BIOS has been correctly updated, enter in the BIOS. The Project Version should be HMIBMI 117

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군

도움이 필요하신가요?

도움이 필요하신가요?

제품 선택기

제품 선택기

애플리케이션에 적합한 제품과 액세서리를 빠르고 쉽게 찾을 수 있습니다.

견적 받기

견적 받기

영업 관련하여 온라인으로 문의하시면 전문가가 연락드립니다.

구매처

구매처

해당 지역의 가장 가까운 슈나이더 일렉트릭 대리점을 쉽게 찾을 수 있습니다.

지원 센터

지원 센터

한 곳에서 모든 요구 사항에 대한 지원 리소스를 찾아보십시오.

  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings