How to open the hardware configuration on a HMI programmed with EOTE?

Issue

It is not clear how to open the hardware configuration on a physical HMI programmed with EcoStruxture Operator Terminal Expert

Product Line

EcoStruxture Operator Terminal Expert

HMI running EOTE, EOTE Runtime

Resolution

There are 2 options to try and open the hardware configuration on an HMI running EOTE

[Option 1]

Display with Touch Gestures

Within 0.5 seconds, touch the top-right then bottom-left corners, or the top-left and bottom-right corners (within a 40 pixel area) of the screen

Open the hardware configuration with gestures

This option can be enabled / disabled from the settings as follows.

1/ In the Project Explorer window, from [System Architecture] click [Target01].

2/ In the Properties window, go to [Function] tab ➞ [Options] tab ➞ [Preference].

Display Hardware Configuration option in EOTE

[Option 2]

Display with Hardware Configuration object on a screen

Note: The size of the object is the size of the Hardware Configuration screen. It is not a button.

Hardware Configuration Tool Part

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군
  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings
  • 환경설정 센터