오늘 무엇을 도와드릴까요?
What is the difference between Harmony XB4 and XB5 range ?
1. What you need to know
Both are Ø22 mm Harmony control and signaling units with the same functions, the same mounting cut-out and the same contact blocks. The difference is the head bezel material: XB4 uses chromium-plated metal, XB5 uses plastic. In the reference structure, "4" means metal and "5" means plastic, while "XB" means a complete unit and "ZB" a component. Heads and fixing collars are not interchangeable between the two ranges.
2. How the two ranges are related
XB4 and XB5 are two material variants of the same modular platform. An operator is built from and only the head and fixing collar are range specific.
- Reference logic: XB4 = complete metal unit, ZB4 = metal component; XB5 = complete plastic unit, ZB5 = plastic component.
- Contact blocks, light modules and most accessories are common to both ranges.
- Metal heads mount on metal collars only (ZB4BZ009); plastic heads on plastic collars only (ZB5AZ009).
- Depending on head type , both ranges can reach up to IP66, IP67, IP69 and IP69K.
- Both XB4 and XB5 are rated for harsh environments.
3. Harmony XB4 metal vs Harmony XB5 plastic
| Criterion | Harmony XB4 (metal) | Harmony XB5 (plastic) |
| Bezel and head material | Chromium-plated metal | Plastic |
| Complete unit prefix | XB4 | XB5 |
| Component prefix | ZB4 | ZB5 |
| Fixing collar | ZB4BZ009 | ZB5AZ009 |
| Body with fixing collar (1 NO) | ZB4BZ101 | ZB5AZ101 |
| Degree of protection | IP66, IP67, IP69, IP69K | IP66, IP67, IP69, IP69K |
| Panel cut-out | Ø22 mm | Ø22 mm |
| Typical selection driver | Shocks and vibrations resistance, aesthetic | Weight, cost, non-conductive bezel, chemicals |
Note : heads and collars cannot be mixed between the two ranges: a ZB4 head does not mount on a ZB5AZ009 collar, and vice versa.
4. Related references
| Function | Reference | Description |
| Complete unit, metal | Metal pushbutton Ø22, flush, green, 1 NO, screw clamp | |
| Complete unit, plastic | Plastic pushbutton Ø22, flush, green, 1 NO, screw clamp | |
| Head, metal | Metal flush pushbutton head, Ø22, green, spring return | |
| Head, plastic | Plastic flush pushbutton head, Ø22, green, spring return | |
| Fixing collar, metal | Metal fixing collar for XB4 / ZB4 heads | |
| Fixing collar, plastic | Plastic fixing collar for XB4 / ZB4 heads | |
| Single NO contact block screw clamp or compact push-in terminals | Single NO contact block screw clamp or compact push-in terminals | |
| Single NC contact block screw clamp or compact push-in terminals | Single NC contact block screw clamp or compact push-in terminals |
Launch Product Selector on se.com to configure a Harmony XB4 or XB5 unit according to your requirements or contact Schneider Electric Technical Support to confirm compatibility with an existing panel.
게시 대상: 슈나이더 일렉트릭 Korea