Video OsiSense XUK9T – How to configure anti-collision mode ?

Place reflector XUZC250 on one crane and sensor on the other crane
Position the reflector right in front of the sensor
Teach the first distance, near or far, and press the Q button for 3 seconds
The green and orange/yellow LEDs are flashing alternately
Now, teach the other distance and when ready, push once again the Q button.
Anti-collision mode is set !  The LED is steady lit up orange/yellow.

-

Return to factory settings of the XUK9T :
  • Power off the sensor
  • Press Q or Qa button and power on the sensor
  • Keep button pressed for 10 seconds until the LEDs blink 3 times synchronously