undefined [object Object]
{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
How can we help you today?
Video OsiSense XX – How to configure the analog output using XXZPB100 teachbutton
Productfamily
OsiSense XX

Teaching the sensing limits by pressing the teachbutton on the XXZPB100 for 3 … 6 seconds, the green LED goes on blinking then release the teachbutton.
Teach the near limit by placing an object near to the sensor and press the teachbutton again and the orange LED goes on.
Now relocate the object to the far limit while the green LED is blinking again and and press the button when the object is at it’s far limit position.
Now the analog output is set as: far limit 4mA and near limit is 20mA

Switching OUTPUT FUNCTION:  4 … 20mA to 20 … 4mA
Push the teachbutton for 6 … 9 seconds, the green LED turns on, then the orange and green LED go blinking and the output state is changed from 4 … 20mA to 20 … 4mA.
Repeating this, the output state will change again.

RESET to default setting ( factory setting ) to withdraw the object, press the teach button for 9 … 15 seconds until both the green and yellow LEDs are blinking then release the botton.