Micrologic Trip Units

To be filled

Part of PacT Series

For PowerPact P- and R-frame and Masterpact NW/NT power circuit breakers.
Micrologic Trip Units Schneider Electric To be filled

Features

PowerPact® P- and R-frame molded case circuit breakers and all Masterpact® power circuit breakers are equipped with the Micrologic® trip system to protect power circuits and loads. Micrologic trip systems use a set of current transformers (called CTs or sensors) to sense the current, a trip unit to evaluate the current m and a tripping solenoid to trip the circuit breaker. Micrologic trip-units are field-interchangeable.

Protection Level

2.0 – LS0: Long Time+ Short Time+ Zero Delay protection, IEC rated
3.0 – LI: Long Time + Instantaneous protection, UL Listed and ANSI Certified
5.0 – LSI: Long Time + Short Time + Instantaneous protection, UL Listed, ANSI Certified, and IEC Rated
6.0 – LSIG: Long Time + Short Time + Instantaneous + Ground fault protection, UL Listed, ANSI Certified, and IEC Rated

ModelsMicrologic (Standard) 2.0, 3.0 and 5.0 Trip Units
  • True RMS sensing
  • LI, LSI trip configurations
  • LS0 trip configuration for IEC
  • Field-interchangeable long-time rating plugs
  • LED long-time pickup indication
  • Test kits available
  • Thermal imaging
Micrologic (Ammeter) 2.0A, 3.0A, 5.0A and 6.0A Trip Units

Includes all features listed for Micrologic standard trip unit, as well as:

  • LI, LSI, LSIG trip configurations
  • LS0 trip configuration for IEC
  • Digital ammeter—phase and neutral (4-pole only)
  • Phase loading bar graph
  • LED trip indication
  • Zone-selective interlocking (ZSI) (short-time & ground-fault)
  • Optional Modbus® communications—PowerLogic® compatible
Micrologic (Power) 5.0P and 6.0P Trip Units

Power measurement and advanced protection features includes all features listed for Micrologic ammeter trip unit, as well as:

  • LSI trip configuration with programmable ground fault alarm
  • LSIG (Ground-fault trip) with programmable ground fault alarm
  • Incremental “fine tuning” of L, S, I, and G pickup and delay settings
  • LCD dot matrix display and LED trip indication
  • Advanced user interface
  • Advanced protection IDMTL—selectable long-time delay bands
  • Neutral protection
  • Power measurement
  • Contact wear indication
  • Modbus communications—PowerLogic compatible
  • Local and remote settings
Micrologic (Harmonic) 5.0H and 6.0H Trip Units

Power quality measurement and advanced protection features. Includes all features listed for the Micrologic P (Power) trip unit, as well as:

  • Enhanced power measurements functions
  • Power quality measurements
Related Products

  • Products Documentation
  • Software Downloads
  • Product Substitution and Replacement
  • Help and Contact Center
  • Find our Offices
  • Get a Quote
  • Where to buy
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • General Terms of Business
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings