Issue:
How to reduce the launching waiting time of control Expert 15.x with floating license ?
Product Line:
EcoStruxure Control Expert
Environment:
EcoStruxure Control Expert
Resolution:
-Edit the Group Policy : WIN +R then enter : gpedit.msc
- Go on Computer Configuration / Windows Settings /
Security Settings / Public Key Policies /Certificate Pass Validation Settings
- from this page select tab Network retrieval, check option Define these policy settings and apply these values:
1 instead of 15 (Default URL) and 2 instead to 20 (Default path validation).