What are the limitations of ISAGRAF ?
For a project
| - |
| Programs |
| 255 |
| grouping_main,_sub_and_child_programs |
| - |
| Levels_in_the_hierarchy |
| 20 |
For names
| - |
| Project |
| 8 char |
| - |
| Program |
| 8 char |
| - |
| Variable |
| 32 char |
| 60 characters for comment |
| - |
| Defined word label |
| 16 char |
| - |
| Defined equivalence |
| 255 char |
| 60 characters for comment |
| - |
| Conversion table |
| 16 char |
| - |
| List of variables |
| 16 char |
| - |
| function / f.block (lib) |
| 8 char |
| this applies to C functions, C function blocks or functions written in IEC languages |
| - |
| function parameter (lib) |
| 16 char |
| this applies to C functions, C function blocks or functions written in IEC languages |
| - |
| IO board |
| 8 char |
| - |
| IO configuration |
| 8 char |
| - |
| Board oem parameter |
| 16 char |
| - |
| Conversion function |
| 8 char |
| - |
| - |
| SFC_rows |
| 600 |
| - |
| SFC_columns |
| 20 |
| - |
| SFC_steps |
| 4095 |
| for_the_whole_project,_grouping_steps,_initial_steps,beginning_and_ending_steps |
| - |
| SFC_transitions |
| 4095 |
| for_the_whole_application |
| - |
| LD/FBD_editing |
| 200_cols |
| - |
| 2000_rows |
| this_is_the_size_of_the_editing_area_in_cell_units. |
| - |
| Quick_LD_editing |
| no_limit |
| limits_are_imposed_by_the_PC_capacity |
| - |
| IL_labels |
| 251 |
| in_the_same_IL_program |
| - |
| Text_editing |
| 40KBytes |
| or_less_according_to_the_system_configuration |
| - |
| - |
| Boolean variables |
| 65535 |
| - |
| Analog variables |
| 65535 |
| grouping integer and real variables |
| - |
| Timers |
| 65535 |
| - |
| Message variables |
| 65535 |
| - |
| Defined words |
| 4095 |
| in the same list (same range) |
| - |
| Defined words |
| 255 |
| used in the same program |
| - |
| Conversion tables |
| 127 |
| used in the application |
| - |
| Points in one table |
| 32 |
| defined in the same conversion table |
| - |
Number of I/O boards including single boards and items of complex equipments cannot exceed 256.
| - |
| IO_Boards |
| 256 |
| defined_for_the_same_application_(boards_or_complex_equipment) |
| - |
| IO_channels |
| 128 |
| on_the_same_board |
| - |
| Functions (IEC lang.) |
| 255 |
| installed together in the library |
| - |
| Function blocks |
| - |
| (IEC lang.) |
| 255 |
| installed together in the library |
| - |
| C functions |
| 255 |
| installed together in the library |
| - |
| C function blocks |
| 255 |
| installed together in the library |
| - |
| function blocks |
| - |
| instances |
| 4095 |
| for the same type of function block in the same application |
| - |
| Function input parameters |
| 31 |
| this applies to C functions and functions written in IEC languages |
| - |
| Function block parameters |
| 32 |
| freely distributed between input and output parameters. At least 1 output parameter is required. |
| - |
| Conversion function |
| 128 |
| installed together in the library |
| - |
| IO configurations |
| 255 |
| installed together in the library |
| - |
| IO boards |
| 255 |
| installed together in the library |
| - |
| Complex IO equipt. |
| 255 |
| installed together in the library |
| - |
| Board oem parameters |
| 16 |
Publié pour: Schneider Electric Belgium




Besoin d'aide ?
Sélectionnez le bon produit
Trouvez rapidement et facilement les produits et accessoires adaptés à vos applications.
Obtenir un devis
Effectuez une demande de renseignements en ligne et un expert vous contactera.
Où acheter ?
Trouvez facilement le distributeur Schneider Electric local le plus proche.
Centre d'aide
Trouvez des ressources de support pour tous vos besoins, en un seul endroit.