Issue
When attempting to access PME Web Applications, the user receives the error:
"You do not have the license required to access this page." 
Product Line
Power Monitoring Expert 8.1
Environment
PME Web Applications
Cause
This issue is caused by the vendor daemon process becoming unresponsive. The symptom is the many feature validator processes running and causing CPU/RAM issues. 
Resolution
The issue has been resolved with the new Floating License Manager version in PME 8.2. It is recommended to upgrade to PME 8.2 in order to resolve this issue.
The following workaround may be used temporarily:
- Stop PME Web Applications and Exit the web browser.
- Stop the ApplicationModules services (AlarmServiceHost, CoreServiceHost, DataServiceHost, and ProviderEngineHost).
- End all the Feature Validator processes via Windows Task Manager.
- Restart the lmadminscheider service.
- Start the ApplicationModules services (AlarmServiceHost, CoreServiceHost, DataServiceHost, and ProviderEngineHost)
Once PME 8.1 Web Applications are running, the issue may not re-occur for a prolonged period of time. Eventually, the steps listed above will need to be performed again as this is only regarded as a temporary fix. Upgrading to PME 8.2 will permanently resolve this issue.
For PME 8.2 installation files, please refer to Where can I download Power Monitoring Expert 8.2 installation files?
Publié pour: Schneider Electric Belgium


Besoin d'aide ?
- Sélectionnez le bon produit- Trouvez rapidement et facilement les produits et accessoires adaptés à vos applications. 
- Obtenir un devis- Effectuez une demande de renseignements en ligne et un expert vous contactera. 
- Où acheter ?- Trouvez facilement le distributeur Schneider Electric local le plus proche. 
- Centre d'aide- Trouvez des ressources de support pour tous vos besoins, en un seul endroit.