Silcon
3 phase UPS power protection with industry leading efficiency and robust performance for data centers and facilities
Tootmisest maas
Presentatsioonid
Toote info
The APC Silcon Series has the load capacity to serve a broad range of electrical equipment - from mainframe computers to Large Corporation-wide installations, production lines, electronic control systems and telecommunication equipment. Up to nine Silcon units can be paralleled to serve special demands for power upgrading or redundancy
Kasulikud omadused
AvailabilityAutomatic internal bypass - Supplies utility power to the connected loads in the event of a UPS power overload or fault.Parallel-capacity capable - Increases total power capacity by using multiple uninterruptible power supplies simultaneously.Intelligent battery management - Maximizes battery performance, life, and reliability through intelligent, precision charging.Generator compatible - Ensures clean, uninterrupted power to protected equipment when generator power is used.200% overload capability - The APC Silcon Series has the ability to supply 200% overload in normal operation for a period of 60 seconds. This enables the system to handle inrush currents, sudden peak loads and output faults without transitioning to bypass. The result is increased availability.Parallel-redundant capable - Power the connected equipment with multiple uninterruptible power supplies to increase system redundancyManageabilityLCD display - Alpha-Numeric Display which displays system parameters and alarms.SmartSlot - Customize UPS capabilities with management cards.Network manageable - Provides remote power management of the UPS over the network.Audible alarms - Provides notification of changing utility power and UPS conditions.Manageable external batteries - Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.Marketing FeaturesInput power factor correction - Eliminates the need for an external phase-compensation unit and minimizes installation costs by enabling the use of smaller generators and cabling.ProtectionLocking cabinet - Prevents unauthorized access to the UPS.Automatic self-test - Periodic battery self-test ensures early detection of a battery that needs to be replaced.Safety-agency approved - Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.Total Cost of OwnershipTemperature-compensated battery charging - Prolongs battery life by regulating the charge voltage according to battery temperature.Input power factor correction - Minimizes installation costs by enabling the use of smaller generators and cabling.Fully-rated power kVA equals kW - Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.Total Cost of OwnershipTemperature-compensated battery charging - Prolongs battery life by regulating the charge voltage according to battery temperature.Input power factor correction - Minimizes installation costs by enabling the use of smaller generators and cabling.Fully-rated power kVA equals kW - Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

