Issue
Installing 'Unity Dif 8 SP3' returns a license error indicating that License Manager version 1.5 is requried.
Product Line
Unity Dif 8 SP3
Environment
Windows 10
Resolution
If you try to install 'Unity Dif 8 SP3' on a PC that already has License Manager version 1.9 installed, the following error could get returned.
This will occur if there is more than one license version listed in the registry after updating the License Manager.
To resolve the issue:
Installing 'Unity Dif 8 SP3' returns a license error indicating that License Manager version 1.5 is requried.
Product Line
Unity Dif 8 SP3
Environment
Windows 10
Resolution
If you try to install 'Unity Dif 8 SP3' on a PC that already has License Manager version 1.9 installed, the following error could get returned.
This will occur if there is more than one license version listed in the registry after updating the License Manager.
To resolve the issue:
- Open the Registry Editor.
- Navigate to the section named 'HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Schneider Electric\License Manager'.
- Backup the 'License Manager' registry key (Right click on the registry key named 'License Manager' and select export)
- -Delete the key for any older version of the License Manager.
- Close the Registry Editor.
- -Retest.
Released for: Schneider Electric Egypt and North East Africa


Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales enquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.