Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   EasyLogic PM1000 series
METSEDM6200 Product picture Schneider Electric
Discontinued

METSEDM6200

Green premium brand logo
METSEDM6200 Product picture Schneider Electric
Discontinued
METSEDM6200
Green premium brand logo

DM6200 digital meter with basic readings - with communication

Show more characteristics
METSEDM6200  has not been replaced. Please contact your customer care centre for more information.
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    PowerLogic
    device short name
    DM6200
    product or component type
    Multimeter
    Complementary
    device application
    Equipment monitoring
    Power monitoring
    Preventive maintenance
    type of measurement
    Current
    Voltage
    Frequency
    Power factor
    Phase unbalance
    Phase angle
    RPM
    [Us] rated supply voltage
    44...277 V AC 50/60 Hz
    44...277 V DC
    network frequency
    45...65 Hz
    maximum power consumption in VA
    3 VA at 240 V AC
    display type
    LED indicator
    sampling rate
    20 samples/cycle
    measurement current
    5 A
    1 A
    analogue input type
    Current 0.05...6 A (impedance <= 0.1 Ohm)
    measurement voltage
    80…480 V AC phase to phase
    measurement accuracy
    Frequency 0.1 %
    Power factor 1 %
    Voltage 1 % 46...277 V
    Current 1 % 0.05...6 A
    communication port protocol
    Modbus
    communication port support
    Terminal block: RS485
    transmission rate
    19.2 kbauds
    Environment
    electromagnetic compatibility
    Electrostatic discharge immunity test: , conforming to IEC 61000-4-2
    Susceptibility to electromagnetic fields: , conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test: , conforming to IEC 61000-4-4
    1.2/50 µs shock waves immunity test: , conforming to IEC 61000-4-5
    Conducted RF disturbances: , conforming to IEC 61000-4-6
    Immunity to impulse waves: , conforming to IEC 61000-4-12
    Conducted and radiated emissions: , A, conforming to CISPR 11
    Immunity to microbreaks and voltage drops: , conforming to IEC 61000-4-11
    mounting mode
    Flush-mounted
    type of installation
    Indoor installation
    overvoltage category
    III
    IP degree of protection
    IP40 back:
    IP51 front face:
    pollution degree
    2
    ambient air temperature for operation
    -10…60 °C
    ambient air temperature for storage
    -25…70 °C
    relative humidity
    95 %
    operating altitude