How can we help you today?

SoMachine/Machine Expert: How to connect PLC/HMIs remotely behind a Router/Modem?

Article available in these languages:

  • Japanese

Since SoMachine V4.1 and Machine Expert, you can make remote connection by using connection mode NodeName via NAT or IP Address via NAT.
You can use one of the remote connected PLCs or HMI as NAT Router.
This remote Nat Router must be reached by port 1105.
If the PLCs are behind a Firewall, you can reach this PLC by forwarding port 1105 to the PLC with the NAT router functionality.
Cisco router


In SoMachine, add the IP address of the Firewall/Router as NAT Address:
SoMachine

Note: Not supported by M262 controllers.

Schneider Electric India

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Contact support - +1800-103-0011
  • Price List
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings