HMI P6 : How to solve the virtual disk service error after a write filter usage ?

The goal of this FaQ is to explain how to solve the 'virtual disk' service error after a write filter usage.

This issue can occur after a volume modification (like Shrink a new system volume).

The device impacted is the Harmony P6 IPC Box.

Procedure steps

  1. Open the Windows task manager.
  2. Reach the β€˜services’ tab
  3. Click on β€˜Open Services’ tab
    Task Manager
  4. Open β€˜Properties’ of β€˜Optimize drives’
  5. Change β€˜Startup type’ from disable to β€˜Automatic (Delayed Start)’


Services

Shrink/Extend feature will work when you have finished the above processes.

Keywords HMIP6, Shrink volume, virtual disk, UWF, write filter