Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
How can we help you today?
How to configure a Read only file in Machine expert so that user can only view and modification is restricted.
Read Only configuration can be achieved by adding User and Groups Management and restricting the permissions or providing limited access to other users.

A sample file is also attached with the user for the sample project is “Owner” and password “Owner”.

Step by step procedure is as below to achieve the requirement.
User

It is necessary to log in as Owner to change the password – first login as Owner is with empty password.

User1
Password of Owner is changed now but still nobody is logged in.

User2

Double click on field Project user: (nobody) to open the Logon filed. Enter Owner and password

User3

Go to Project -> User Management -> Permissions… Select all entries located under Commands -> Execute Set Deny for group Everyone

User4

Select all entries located under Object type -> Create Set Deny for group Everyone

User5

Select MyController under Project objects -> Add or remove children Set Deny for group Everyone.

User6

Select MyController under Project objects -> Modify Set Deny for group Everyone

User7

Select MyController under Project objects -> Remove Set Deny for group Everyone

User8

Select MyController under Project objects -> View Set Grant for group Everyone

User9

Now some settings need to be adapted, so that Everyone can… - open the project - set an active path to a controller - compile the application - download the application - start / stop the application - close the project

Select the objects shown below from Commands -> Execute and select Grant
User10
User11

User12

User13
User14
User15
User16

Close the Permissions dialog, close all windows, save project, close project, re-open it, do not logon.
Click Cancel and acknowledge the following message (both twice)

User17

Now you have access to the project without permission to add/remove/change the application/code.

Schneider Electric India

Attachment(s)
User-Groups.project [3.12 MB]
Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: