PowerChute is flagged a vulnerable to CVE-2026-49844

Issue:

PowerChute is flagged a vulnerable to CVE-2026-49844

Product:

PowerChute Serial Shutdown 1.6

PowerChute Network Shutdown 5.2

Environment:

All supported operating systems.

Cause:

PowerChute Serial Shutdown v1.6 ships with Log4j version 2.25.4

PowerChute Network Shutdown v5.2 ships with Log4j version 2.25.3

Solution:

For PowerChute Serial Shutdown 1.6 on Windows:

  1. Download the attached file PCSS1.6_log4j_update.zip file
  2. Uncompress the file PCSS1.6_log4j_update.zip
  3. Open a command prompt as an administrator
  4. Change directory to the PCSS1.6_log4j_update directory that was created when the zip file PCSS1.6_log4j_update.zip was uncompressed.
  5. Run the command run_patch.cmd

The patch will remove the current log4j files and replace them with log4j version 2.26.1.

For PowerChute Network Shutdown 5.2 on Windows:

  1. Download the attached file PCNS5.2_log4j_update.zip file
  2. Uncompress the file PCNS5.2_log4j_update.zip
  3. Open a command prompt as an administrator
  4. Change directory to the PCSS5.2_log4j_update directory that was created when the zip file PCSS5.2_log4j_update.zip was uncompressed.
  5. Run the command run_patch.cmd

The patch will remove the current log4j files and replace them with log4j version 2.26.1.

NOTE: Files to update the PCSS 1.6 and PCNS 5.2 log4j files on Linux OS will be added soon.

Schneider Electric India

Attachment(s)
PCSS1.6_log4j_update.zip [2.02 MB]
PCNS5.2_log4j_update.zip [2.03 MB]
Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Contact support - +1800-103-0011
  • Price List
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings