AccuSine SWP

The solution for harmonic filtering in buildings

-
AccuSine SWP Schneider Electric The solution for harmonic filtering in buildings

Features

  • Global compensation or individual harmonic compensation, from H2 to H50, global or selective
  • Reactive compensation: power factor correction, cos φ to near unity, selectable set point.
  • Electrical systems: 3-wire or 4-wire.
  • Neutral current correction: 3 times unit rating.
  • Product standards: CE Certified.
  • Parallel capability: up to 4 like units.
  • Enclosure type: IP20, wall mounted.
  • Communication: 3 dry (voltage free) contacts to monitor status from remote location; Standard RS422/485 link for J-Bus and Modbus.
  • Functionality: harmonic mitigation or power factor correction, separately or combined.
  • Human Machine Interface: graphic display, seven languages.

Technical Data

  • System input
    • Nominal voltage: 400 V -20 + 15%; other voltages with transformer
    • Nominal frequency: 50Hz, 60 Hz, +/-8%
  • Number of phases: 3 phases with or without neutral

  • Technical characteristics
    • Compensated harmonic currents: H2 to 50, full compensation or individual compensation.
    • Fast response at < 2 cycles
    • Overload: possibility of continuous operation with current limitation.

  • Environmental conditions
    • 0 °C to 40 °C continuous (derate 2 %/1 °C to 50 °C)
    • Relative humidity: 0 to 95 % without condensation
    • Operating altitude: < 1000 m, (derate 1 %/100 m above)
    • Reference technical standards: IEC/EN

Benefits

  • AccuSine SWP  is extremely compact. It can be wall-mounted or installed in a switchgear cubicle;
  • AccuSine SWP  can be connected in parallel, allowing future increases in power demand without disconnecting the supply;
  • AccuSine SWP  adapts automatically to any single-phase or three-phase load: computer load, variable speed drives, etc. It is compatible with any type of neutral systems.

Applications

By neutralising harmonics AccuSine SWP  eliminates:

  • nuisance tripping of circuit-breakers,
  • Premature ageing of equipment.

By correcting the cos., AccuSine SWP  allows:

  • energy savings,
  • Full compatibility of generator sets with capacitive loads
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Contact support - +1800-103-0011
  • Price List
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings