I Line II

Aluminium with Copper Contact Busway : 800A-5000AAluminium with Copper Contact Busway : 800A-5000A, Copper Busway : 630A-6300A

Part of Line Series

'Delivering power across 2.9M sq. Km'
I Line II Schneider Electric Aluminium with Copper Contact Busway : 800A-5000AAluminium with Copper Contact Busway : 800A-5000A, Copper Busway : 630A-6300A

Features

Copper (Copper busway)
630A – 6300A
  • 99.97% purity of copper
  • Silver plated copper in full length
  • minimize surface oxygenation, assure low surface contact resistance and low voltage drop

Aluminum with copper contact (Copper Contact busway)
800A – 5000A

  • Use silver-plated Bi-metal cladding on Aluminum conductor through high current and high pressure.
  • Special process enabling molecular fusion of Copper and Aluminum through the use of very high pressure and temperature.
  • All of connection zone are silver to silver.
  • Conductors full-length insulated using Mylar film, class B, 130C
  • Available polarities: 3L +PE, 3L +N+PE
  • Maximum rated voltage: 1000 Volts
  • Insulation voltage: 1000 Volts
  • Integral Earth Bus : The earthing bus completely encloses the bus sandwich and rated at 50% capacity.
  • Joint-Pak :Standard on I-LINE II system. It allows for quick removal of lengths from the busbar trunking runs for load shifting or maintenance.
      • Single bolt connection makes installation faster
      • Belleville washer provides equal pressure across the complete joint contact area to assure proper electrical contact
      • Adjustable range: +/- 3mm

Degree of Protection : IP 40 – IP66


Benefits

  • A total coordinated, compact, simple and flexible power distribution system
  • Safety of Life and property with reduced risk of exposure to electromagnetic fields.
  • Fully recyclable and helps conserve natural resources
  • Seismic compliance for projects under seismic conditions

Applications

  • Transformer/ Switchboard connection
  • Horizontal distribution, from the substation to the loads in workshop
  • Vertical distribution, from the substation to the loads of each high rise floor
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers