ION Enterprise 5.0 Install Problems on French Windows XP Operating System

Goals and Symptoms

Summary

ION Enterprise 5.0 does not install successfully on a computer running the French version of Windows XP.  The files are installed, but due to a database upgrade error, a number of setup steps that should be performed after the reboot do not succeed. The system is left in an unusable state.

Symptoms

When the ION Enterprise 5.0 Installer is run on the French version of Windows XP, the installation proceeds normally until after the reboot.  At this time the following error is seen:

ERROR:(-2147221104) Upgrading ION_Network database: PMLMSDEUpgrader: Could not upgrade MSDE Database: Type incompatible

When the installer completes, none of the services are created.  The server name is not added to the ION_Network database.  The product key is not entered into the ION_Network database.  The system is not useable.

Rerunning the installer does not correct the problem.

Facts and Changes

Keywords

ION Enterprise 5.0, French Windows XP

Causes and Fixes

Cause

There is a coding error in MSDEUpgrader.dll that results in a Visual Basic error for a particular comparison.  This is a problem for operating systems that use the comma rather than the period as the number decimal separator.  This error was corrected in the version of the file shipped with ION Enterprise 5.0 SP3.

The Visual Basic error prevents the Installer from completing the final steps of the installation process.

Resolution

This problem does not exist for ION Enterprise 5.5.  If you must install ION Enterprise 5.0, refer to the Workaround below.

Workaround

Follow the steps below:

  • 1. Run the ION Enterprise 5.0 installer. (It will fail as described above.)
    2. Run the ION Enterprise 5.0 Service Pack 3 installer.
    3. Re-run the ION Enterprise 5.0 installer.

More Information

The workaround solves the problem by using the Service Pack 3 installer to replace the file (MSDEUpgrader.dll) that is generating the error.  When the ION Enterprise 5.0 installer is re-run, it will use the updated Service Pack 3 files and the final setup steps will complete successfully.

Original article#11009


Legacy KB System (APS) Data: RESL182946 V1.0, Originally authored by DaMi on 03/20/2007, Last Edited by DaMi on 03/20/2007
Related ranges: ION Enterprise

슈나이더 일렉트릭 Korea

도움이 필요하신가요?

  • 제품 선택기

    애플리케이션에 적합한 제품과 액세서리를 빠르고 쉽게 찾을 수 있습니다.

  • 견적 받기

    영업 관련하여 온라인으로 문의하시면 전문가가 연락드립니다.

  • 구매처

    해당 지역의 가장 가까운 슈나이더 일렉트릭 대리점을 쉽게 찾을 수 있습니다.

  • 지원 센터

    한 곳에서 모든 요구 사항에 대한 지원 리소스를 찾아보십시오.

  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings