Unable to assign an IP address to a Unity Momentum processor using a Bootp or DHCP server
Issue
The purpose of this resolution is to inform users of the Unity Momentum processors that an issue exists when attempting to assign an IP address.
When a new 171CBU9809x is powered up, right out of the box, it does not send out any bootp requests. After the PLC is powered on and it completes its boot up routine, the 'ETH STS' LED immediately blinks 6x (operating using default IP address). Therefore, no IP was assigned via a bootp or DHCP server. The only method to assign an IP address was to manually load a configuration to the PLC via USB with an IP address configured.
The issue occurs with 171CBU9809x firmware v.1.00 and v1.20.
Product Line
171CBU98090
171CBU98091
Resolution
The issue was resolved in firmware version 1.21.
The purpose of this resolution is to inform users of the Unity Momentum processors that an issue exists when attempting to assign an IP address.
When a new 171CBU9809x is powered up, right out of the box, it does not send out any bootp requests. After the PLC is powered on and it completes its boot up routine, the 'ETH STS' LED immediately blinks 6x (operating using default IP address). Therefore, no IP was assigned via a bootp or DHCP server. The only method to assign an IP address was to manually load a configuration to the PLC via USB with an IP address configured.
The issue occurs with 171CBU9809x firmware v.1.00 and v1.20.
Product Line
171CBU98090
171CBU98091
Resolution
The issue was resolved in firmware version 1.21.
게시 대상: 슈나이더 일렉트릭 Korea


도움이 필요하신가요?
제품 선택기
애플리케이션에 적합한 제품과 액세서리를 빠르고 쉽게 찾을 수 있습니다.
견적 받기
영업 관련하여 온라인으로 문의하시면 전문가가 연락드립니다.
구매처
해당 지역의 가장 가까운 슈나이더 일렉트릭 대리점을 쉽게 찾을 수 있습니다.
지원 센터
한 곳에서 모든 요구 사항에 대한 지원 리소스를 찾아보십시오.