Can all contact blocks be used for the 30mm range joysticks? [Video]

Question:
Can all contact blocks be used for the 30mm range joysticks?

Product String Reference:

  1. Top Level > Product Category > Industry > Industry Control & Drives > Control, Relays & Sign > Diameter 30.
  2. Top Level > PR_Product_OPS_Structure > Pushbuttons, Switches, Pilot Lights and Joysticks > 30mm Push Buttons > Harmony 30mm 9001K Metal Push Buttons

Objective:
The objective of this video is to provide an in-depth analysis of contact blocks and their application.



Product Line:
IDSIG - CONTROL, RELAYS & SIGN.

Environment:
N/A

Resolution:

When used in conjunction with a Harmony range push button, the:
  1. Combination N/O + N/C, N/C opens and N/O closes
  2. N/C contact opens when push button is depressed
  3. N/O contact closes when push button is depressed

When used in conjunction with the 30mm range joystick application.
  1. Combination N/O + N/C will stay open so that it is neither open nor closed
  2. N/C contact is open
  3. N/O contact is open
When the joystick is maneuvered, the:
  1. Combination N/O + N/C will close at different positions of the joystick handle.
  2. N/C will close
  3. N/O will close

As such, these contacts do not act in the same way for a joystick as they do for the Harmony range push button application.

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군
  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings