Чем мы можем помочь сегодня?

TCP and UDP ports used by each component of PowerChute.

Article available in these languages:

Issue:
What TCP and UDP ports are used by each component of PowerChute

Product Line:
PowerChute Business Edition
PowerChute Serial Shutdown

For information concerning PowerChute Network Shutdown, see Schneider Electric FAQ . What ports are utilized by PowerChute Network Shutdown and how are they secured? ​​​​​​​

Environment:
All supported OS

Cause:
Informational

Solution:

TCP
6547 – Agent Web UI (PowerChute Business Edition  v10.x and PowerChute Serial Shutdown v1.x)

UDP
161– PowerChute SNMP Agent

NOTE: Port 6547 must be open in the PC/Servers firewall to allow access to the Agent web UI, and port 161 must be open if SNMP access is required.

PowerChute allows you to create only one administrator account. This account has a unique login username and password, enabling full read/write access. It is strongly recommended that PowerChute not be made available on a public-facing network segment. This is to ensure secure user control. To further restrict access, TCP port 6547 (HTTPS) can be blocked using firewall settings to prevent remote access to the UI. The UI can still be accessed for the system running the software at https://localhost:6547.

It is recommended that you use a well-configured firewall in conjunction with an intrusion prevention system (IPS) to help protect PowerChute against Denial-of-Service attacks and unauthorized access.

  • The firewall can be used to block access from untrusted/external networks and allow access only from trusted subnets.
  • The IPS can be used to detect patterns of behavior associated with Denial of Service attacks.

It is strongly recommended that PowerChute is deployed in a secure location, where the PowerChute server and connected UPS are protected by physical restraints that prevent unauthorized access, and where access is restricted to those who maintain the equipment.

Schneider Electric Казахстан

Узнайте больше

Узнайте больше

Нужна помощь?

Инструмент для подбора продукции

Быстро и легко находите подходящие продукты и принадлежности для ваших условий применения.

Получить коммерческое предложение

Заполните заявку онлайн, и с вами свяжется наш эксперт.

Где купить?

Легко находите ближайшего к вам дистрибьютора Schneider Electric.

Центр поддержки

Находите ресурсы поддержки для всех ваших потребностей в одном месте.