Customer didn't know how the speed signal was wired in the ATV212 S-Flex.
Resolution:
Yes, a 0-10Vdc, 0-20mA, or a 4-20mA analog signal can be wired to the VIA Terminal on the drive.
Only a 0-10v or PTC motor thermal probe can be used with terminal VIB.
NOTE: Dipswitches are used to set these terminals for Voltage, Current or PTC.