How can I utilize a user built keypad as an input for a data display in Vijeo Designer?

Issue:
Utilizing the user built keypad as an input for a data display in Vijeo Designer


Product Line:
Vijeo Designer


Resolution:
The following screenshot is a panel in Vijeo Designer with a data display and user built keypad.
keyboard Select the variable for the data display under the "General" tab.
Edit the data display to enable "Enable Input Mode" and disable the "Display Popup Keypad".
settings
This action will allow the user built keypad to be the input for the data display when you touch the data display on the XBTG terminal.