Issue:
Receiving the following error message from the Reporting Services Report Server application when
requesting the following ReportServer URL : http://localhost/ReportServer/
Product:
Power Monitoring Expert 7.0.1
ION Enterprise 6.0.x
ION EEM
Environment:
Microsoft Reporting Services
Cause:
Although the problem seems to be a SQL Server Reporting Services SSRS problem, actually it is caused by the incorrect configuration of
Report Server application pool in the Internet Information Services IIS web server.
Resolution:
The solution is to change the ASP.net version of the the ReportServer application pool version from 4.0 to 2.0.50727.

Receiving the following error message from the Reporting Services Report Server application when
requesting the following ReportServer URL : http://localhost/ReportServer/
Server Error in '/ReportServer' Application
Could not find permission set named 'ASP.Net'.

Could not find permission set named 'ASP.Net'.
Product:
Power Monitoring Expert 7.0.1
ION Enterprise 6.0.x
ION EEM
Environment:
Microsoft Reporting Services
Cause:
Although the problem seems to be a SQL Server Reporting Services SSRS problem, actually it is caused by the incorrect configuration of
Report Server application pool in the Internet Information Services IIS web server.
Resolution:
The solution is to change the ASP.net version of the the ReportServer application pool version from 4.0 to 2.0.50727.
Опубликовано для:Schneider Electric Казахстан

