Чем мы можем помочь сегодня?
How to Terminate All Sessions Prior to Restoring a Database
Issue
Cannot restore a database. The Restore Database operation fails, reporting that exclusive access could not be obtained because the database is in use.
Product
Power Monitoring Expert 7.2.x
Power Monitoring Expert 8.x
Power Monitoring Expert 9.0
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Power Monitoring Expert 2024
Environment
SQL Server
Cause
Before an existing database can be restored, there should be no connections using the database. If the database is currently in use the RESTORE command fails with below error:
Exclusive access could not be obtained because the database is in use.
Msg 3013, Level 16, State 1, Line 2
RESTORE DATABASE is terminating abnormally.
Resolution
To avoid this, we need to terminate all sessions that use the database. All sessions using the database can be obtained
by executing the system stored procedure sp_who2 or by querying the sys.dm_exec_sessions table as:
SELECT session_id
FROM sys.dm_exec_sessions
WHERE DB_NAME(database_id) = 'RestoringDatabaseName'You need to terminate each of the sessions returned individually by using KILL command.
If there are a large number of sessions to terminate, or you need to do this on a routinely,this can be a lengthy and tedious process.
You can *automate* this using below script, which takes the database name as input, and terminates all sessions connecting to it.
USE [master]
GO
DECLARE @dbName SYSNAME
DECLARE @sqlCmd VARCHAR(MAX)
SET @sqlCmd = ''
SET @dbName = 'RestoringDatabaseName' -- Change database name here
SELECT @sqlCmd = @sqlCmd + 'KILL ' + CAST(session_id AS VARCHAR) +
CHAR(13)
FROM sys.dm_exec_sessions
WHERE DB_NAME(database_id) = @dbName
PRINT @sqlCmd
--Uncomment below line to kill
--EXEC (@sqlCmd)
** see attachment containing the SQL script text
Опубликовано для: Schneider Electric Казахстан
Вложения
Узнайте больше
Изделие:
Узнайте больше
Изделие:
Нужна помощь?
Инструмент для подбора продукции
Быстро и легко находите подходящие продукты и принадлежности для ваших условий применения.
Получить коммерческое предложение
Заполните заявку онлайн, и с вами свяжется наш эксперт.
Где купить?
Легко находите ближайшего к вам дистрибьютора Schneider Electric.
Центр поддержки
Находите ресурсы поддержки для всех ваших потребностей в одном месте.