Issue:
How do you set the backlight timeout in the VW3A1111 keypad?
Product Line:
Altivar Process Drives using the VW3A1111 keypad
Environment:
All
Cause:
Preference
Resolution:
There is parameter for standby timeout in VW3A1111 with default value 60s. It is possible to set it to 'NO'. This parameter is stored in the remote keypad (not in drive). How to change it depends on the drive being used.
ATV32/ATV320:
Main menu -> interface -> Display config. -> LCD Settings -> Stand-by delay
Note: access level has to be set to expert
ATV630/ATV930/ATV340:
Main menu -> My preferences -> LCD settings ->Stand by
ATV61/ATV71
Main menu -> Display config. -> LCD Settings -> Stand-by delay
Note: access level has to be set to expert
How do you set the backlight timeout in the VW3A1111 keypad?
Product Line:
Altivar Process Drives using the VW3A1111 keypad
Environment:
All
Cause:
Preference
Resolution:
There is parameter for standby timeout in VW3A1111 with default value 60s. It is possible to set it to 'NO'. This parameter is stored in the remote keypad (not in drive). How to change it depends on the drive being used.
ATV32/ATV320:
Main menu -> interface -> Display config. -> LCD Settings -> Stand-by delay
Note: access level has to be set to expert
ATV630/ATV930/ATV340:
Main menu -> My preferences -> LCD settings ->Stand by
ATV61/ATV71
Main menu -> Display config. -> LCD Settings -> Stand-by delay
Note: access level has to be set to expert
Опубликовано для: Schneider Electric Казахстан









