Чем мы можем помочь сегодня?

Does PME Web Applications use SOAP (simple object access protocol) or WSDL (web services description language)?

Issue
A customer would like to know if PME Web Applications use SOAP (simple object access protocol) or WSDL (web services description language).

Product Line
Power Monitoring Expert 7.x

Power Monitoring Expert 8.x

Power Monitoring Expert 9.x

Power Monitoring Expert 2020

Power Monitoring Expert 2021

Power Monitoring Expert 2022

Power Monitoring Expert 2023

Power Monitoring Expert 2024

Environment
Web Applications

Resolution
Both SOAP and WSDL are used.
SOAP is the protocol that several services in PME use.
WSDL is short for Web Service Description Language. It is a metadata format that describes the services and how to interact with it programmatically.

SOAP - technology used to implement the service.
WSDL - describes how the system works

To see this in PME browse to the following url http://localhost/IONReportDataService/ReportDataService.asmx. To see the WSDL click the link Service Description. You should see a bunch of XML describing the service, eg methods you can call, parameters and return values.

Click back and now click GetViewData. You get more XML but this show the sample SOAP messages the service will use internally.

Our more modern services for apps like dashboards etc do not use SOAP or WSDL. Rather they are REST style services which use JSON.

Schneider Electric Казахстан

Узнайте больше

Узнайте больше

Нужна помощь?

Инструмент для подбора продукции

Быстро и легко находите подходящие продукты и принадлежности для ваших условий применения.

Получить коммерческое предложение

Заполните заявку онлайн, и с вами свяжется наш эксперт.

Где купить?

Легко находите ближайшего к вам дистрибьютора Schneider Electric.

Центр поддержки

Находите ресурсы поддержки для всех ваших потребностей в одном месте.