Чем мы можем помочь сегодня?
Data Center Expert | Migrating from a Physical Appliance to a Virtual Appliance
Issue:
How do I migrate from a DCE hardware server to a virtual server?
Product Line:
StruxureWare Data Center Expert (DCE)
- Basic Appliance (AP9465)
- Standard Appliance (AP9470)
- Enterprise Appliance (AP9475)
- Virtual Appliance (AP94VMACT)
Environment:
StruxureWare Data Center Expert (all versions)
Physical to Virtual (VMware ESXi) Migration
Cause:
As the data center is moving away from hardware servers and towards vitalization, many of our customers are looking to migrate StruxureWare DCE from a hardware to a virtual environment.
Resolution:
Since v9.0, DCE has migrated to subscription licenses. The process of migrating physical server will have differences based on current version of physical server. This will be addressed below depending on the current version of physical server.
Physical server with v8.3.0 and below:
In order to migrate from a hardware to a virtual DCE server, there are a number of things you need to do.
1) You must purchase the AP94VMACT activation key to activate the free AP94VMTRL trial virtual machine.
2) Download and deploy the AP94VMTRL free DCE trial VM. Please be sure it is the same version as the hardware server from which you wish to migrate.
3) During deployment of the trial VM, please be sure to add a second NIC card to accommodate the private LAN NIC from the hardware server and add a second hard drive to at least match the hard drive space of the hardware from which you are deploying. NEVER CHANGE the base hard drive deployed with the VM. These changes (at least the NIC addition) should be done prior to the first boot up of the DCE VM. Review Data Center Expert | Configuring Hardware Resources (RAM, CPU, Hard Disks, & Network Adapters) to adjust CPU and RAM to match your deployment.
4) Boot the VM, set the IP. (If your keeping the same IP address as the physical server, ensure the physical server is turned off at this point.) Video: Data Center Expert | How do I configure the network settings? Import the backup you've just created from the hardware server.
5) In the desktop client, HELP-ABOUT Data Center Expert note the new MAC address and serial number, then contact DCIM technical support. The newly deployed VM will have a different MAC address than the hardware server. License keys are tied to the MAC address so they will not work on the new server. Ensure to have your old MAC address to provide to technical support. After verifying support contracts for the license keys and the server itself, technical support can reset the license key passcodes so that they may be used again to license the virtual server. Technical support will work with the contract administrators to switch the support contracts to the new servers/licenses. They will help generate new licenses that can be viewed at https://ecostruxure-it-entitlements.se.com.
6) Import the new license keys (starting with the VM activation key) created from the previous registration step in the desktop client. It is now recommended to create another backup.
Physical server with 9.0 and above:
1) Ensure first that the current physical server has active subscription license.
2) Download and deploy the AP94VMTRL free DCE trial VM. Please be sure it is the same version as the hardware server from which you wish to migrate.
3) During deployment of the trial VM, please be sure to add a second NIC card to accommodate the private LAN NIC from the hardware server and add a second hard drive to at least match the hard drive space of the hardware from which you are deploying. NEVER CHANGE the base hard drive deployed with the VM. These changes (at least the NIC addition) should be done prior to the first boot up of the DCE VM. Review Data Center Expert | Configuring Hardware Resources (RAM, CPU, Hard Disks, & Network Adapters) to adjust CPU and RAM to match your deployment.
4) Boot the VM, set the IP. (If your keeping the same IP address as the physical server, ensure the physical server is turned off at this point.) Video: Data Center Expert | How do I configure the network settings? Import the backup you've just created from the hardware server.
5) With subscription license, customers can migrate the license by themselves from their mySchneider account ONE-TIME only. This is to give way to scenario such as migration of server from physical to virtual. Subscription license is tied to MAC Address (if physical) or Server ID (if virtual).
- Register the newly deployed virtual server with its Server ID that can be found from desktop client System > License. Click the copy button and use it on server registration on mySchneider. Add your Data Center Expert device to mySchneider Software Management
- On mySchneider account, find the physical server and click Action button (three dots) then choose Transfer (rehost) licenses from the drop down. Server is now dissociated.
- Add the license to virtual server following the steps here: Add License to your Data Center Expert device
- Finally, Activate License in Data Center Expert
Опубликовано для: Schneider Electric Казахстан
Узнайте больше
Линейка:
Узнайте больше
Линейка:
Нужна помощь?
Инструмент для подбора продукции
Быстро и легко находите подходящие продукты и принадлежности для ваших условий применения.
Получить коммерческое предложение
Заполните заявку онлайн, и с вами свяжется наш эксперт.
Где купить?
Легко находите ближайшего к вам дистрибьютора Schneider Electric.
Центр поддержки
Находите ресурсы поддержки для всех ваших потребностей в одном месте.