Чем мы можем помочь сегодня?
PlantStruxure PES [V3.1 -> V4.3] & EcoStruxure Hybrid DCS [2018]: embedded Versions
Goals and Symptoms
Provide list of participants versions delivered per release
Facts and Changes
| Release Version | Operating system of the workstation PES Server/Eng client/Operation server & client | Operating system of the virtual machine | Unity Pro | Vijeo Citect | OFS | Date of delivery |
| PES V3.1 | Windows 7 Pro (x32 & x64) | Windows 7 Pro | V7.0 | V7.30 | V3.40 | June 2013 |
| PES V3.1 SP1 | Windows 7 Pro (x32 & x64) | Windows 7 Pro | V7.0 | V7.30 | V3.40 SP4 | October 2013 |
| PES V4.0 | Windows Server 2012, Windows 7, 8.1 Pro (x32 & x64) | Windows 7 Pro | V8.1 | V7.40 SP1 | V3.5 SP3 | January 2015 |
| PES V4.0 SP1 | Windows Server 2012, Windows 7, 8.1 Pro (x32 & x64) | Windows 7 Pro | V8.1 | V7.40 SP1 | V3.5 SP3 | September 2015 |
| PES V4.1 | Windows Server 2012, Windows 7, 8.1 Pro (x32 & x64) | Windows 7 Pro | V10 | V7.40 SP1 | V3.5 SP3 | February 2016 |
| PES V4.2 | Windows Server 2012, Windows 7, 8.1 Pro (x64) Operation client: Windows 7, 8.1 Pro (x32) | Windows 7 Pro | V11.0 + HF1, HF PES_adaptation | 2015/V7.50 SP1 | V3.5 SP8 | June 2016 |
| PES V4.2 SP1 | Windows Server 2012, Windows 7, 8.1 Pro (x64) Operation client: Windows 7, 8.1 Pro (x32) | Windows 7 Pro | V11.0 + HF1, HF PES_adaptation | 2015/V7.50 SP1 | V3.5 SP8 | November 2016 |
| PES V4.2 SP2 | Windows Server 2012, Windows 7, 8.1 Pro (x64) Operation client: Windows 7, 8.1 Pro (x32) | Windows 7 Pro | V11.0 + HF1, HF PES_adaptation | 2015/V7.50 SP1 | V3.5 SP8 | January 2017 |
| PES V4.2 SP3 | Windows Server 2012, Windows 7, 8.1 Pro (x64) Operation client: Windows 7, 8.1 Pro (x32) | Windows 7 Pro | V11.0 + HF1, HF PES_adaptation | 2015/V7.50 SP1 | V3.5 SP8 | April 2017 |
| PES V4.3 | Windows Server 2012, Windows 7, 8.1 Pro (x64) Operation client: Windows 7, 8.1 Pro (x32) | Windows 7 Pro | V11.0 + HF1, HF PES_adaptation (Simulator V11) | 2015/V7.50 SP1 + Patch11 | V3.60 SP3 | June 2017 |
| PES V4.3 SP1 | Windows Server 2012, Windows 7, 8.1 Pro (x64) Operation client: Windows 7, 8.1 Pro (x32) | Windows 7 Pro | V11.0 + HF1, HF PES_adaptation (Simulator V11) | 2015/V7.50 SP1 + Patch11 | V3.60 SP3 | November 2017 |
| Hybrid DCS 2018 | Windows Server 2012, Windows 7, 8.1, 10 Pro (x64) | Windows 10 Pro | V13 | Citect 2016 | V3.60 | July 2018 |
Опубликовано для: Schneider Electric Казахстан
Узнайте больше
Линейка:
Узнайте больше
Линейка:
Нужна помощь?
Инструмент для подбора продукции
Быстро и легко находите подходящие продукты и принадлежности для ваших условий применения.
Получить коммерческое предложение
Заполните заявку онлайн, и с вами свяжется наш эксперт.
Где купить?
Легко находите ближайшего к вам дистрибьютора Schneider Electric.
Центр поддержки
Находите ресурсы поддержки для всех ваших потребностей в одном месте.