Concept to Unity Pro/Control Expert: "convert step failed' when importing a Concept .ASC file.
Issue:
Concept to Unity Pro/Control Expert: "convert step failed' when importing a Concept .ASC file
Product Line:
Concept to Unity/ Control Expert
Resolution:
This usually occurs because the Concept project has been exported out of the Concept Converter using
the "Reconnect as Equal' switch.
It should be exported using the first choice, "With all used DFBs".
If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.