Problem:
The application failed to start because its Side-by-Side configuration is incorrect. Please see the application event log or use the command-line sxstrace.exe tool for more derails.
using windows event viewer>windows logs>applications; to view events that have occurred on your computer.
If the error indicates Dependent Assembly Microsoft.VC80.MFC,processorArchitecture="x86",publicKeyToken="1fc8b3b9a1e18e3b",type="win32",
version could not be found.
Follow the steps below:
- Uninstall the SCADAPack E configurator.
- Install the C++ 2005 redistributable using the link below.
https://www.microsoft.com/en-us/download/details.aspx?id=26347
- Re install the SCADAPack E configurator.
Опубликовано для: Schneider Electric Казахстан
Discontinued
Discontinued
Discontinued
Discontinued
Discontinued
Discontinued
Discontinued
Discontinued
Discontinued
Discontinued