Auxiliary contact, Acti9 A9N, OF/SD+OF, 2 C/O, 100mA to 6A, 24VAC to 415VAC, 24VDC to 130VDC, top and bottom connection

A9N26909

Can report the signaling to an Open/Closed or an Opening for Default Devices status
Compatible with standard applications with current from 100mA up to 6A
Compatible with Acti9 C120/C60H-DC
To be fixed with clips directly on the left of the MCB
Environmental Data
Total lifecycle Carbon footprint
2
Use Better
Packaging made with recycled cardboard
information_stroke
Recycled cardboard content is minimum 70% (50% in US). Some orders may include non-recycled cardboard until stock runs out.
No
Use Again
Take-back
information_stroke
Whether the product has been included in a global take-back program. Some products are eligible in some geographies, please verify if it's available in your country.
No
Description
arrow2_down
This Acti9 electrical auxiliary is a modular double OC or fault contact. The 2 contacts (2 NO/NC) can report the signalling information of the associated device. In AC network, the In rated current is 6A at 24VAC to 240VAC and 3A at 415VAC with operating frequency of 50Hz to 60Hz. In DC network, the In rated current is 6A at 24VDC, 2A at 48VDC, 1.5A at 60VDC and 1A at 130VDC. It is intended for new or renovated installation in small commercial and buildings. This OC contact is compatible with Acti9 ranges such as C120, C60H-DC, SW60-DC, C60PV-DC, and xC60. The OF and OF or OF and SD is either used for device short name or compatibility code. The mechanical indicator is provided within the product for local signalling. It has a screw clamp terminal connection at top and bottom. The connection allows rigid copper cable with a cable cross section of 0.5mm² to 2.5mm². It has a screw clamp terminal connection at top and bottom. The connection allows flexible copper cables (2 cables) with a cable cross section of 1.5mm². It has a screw clamp terminal connection at top and bottom. The connection allows flexible with ferrule copper cables (2 cables) with a cable cross section of 1.5mm². The Ui rated insulation voltage is up to 500V. It has a Uimp rated impulse withstand voltage of 4kV. It can be mounted on DIN rail for modular installation. The width in 9mm pitches is 1. The dimensions are (W) 9mm x (H) 90mm x (D) 68mm. The product colour is white. The product weight is 38g. The pollution degree is 3. The level of tropicalisation is treatment 2. The wire stripping length is 9mm. The tightening torque of connection is 1N.m (top and bottom) for PZ1 screwdriver type. The IP degree of protection is IP20. The operating temperature is from -25°C to +50°C. The storage temperature is from -40°C to +85°C. This product complies with EN/IEC 60947-5-1 and GB/T 14048.5 standards. It has EAC and CCC quality labels and certified with CE and UKCA certifications.
Specifications
arrow2_down
Main
range of productActi9
Product or component typeDouble OC or fault contact
Device short nameOF and OF or OF and SD
Signal contacts composition2 C/O
[In] rated current0.1…6 A at 24...250 V, AC 50/60 Hz
0.1…6 A at 24...240 V, AC 50/60 Hz
0.1…3 A at 415 V, AC 50/60 Hz
0.1…6 A at 24 V, DC
0.1…2 A at 48 V, DC
0.1…1.5 A at 60 V, DC
0.1…1 A at 130 V, DC
9 mm pitches1
StandardsEN/IEC 60947-5-1
GB/T 14048.5
Product certificationsCE
UKCA
Quality labelsEAC
CCC
Complementary
[Ui] rated insulation voltage500 V
[Uimp] rated impulse withstand voltage4 kV
Local signallingMechanical indicator
Mounting modeClip-on
Mounting locationLeft side of circuit-breaker
Mounting supportDIN rail
Comb busbar and distribution block compatibilityNO
Height90 mm
Width9 mm
Depth68 mm
Net weight38 g
ColourWhite
Connections - terminalsScrew clamp terminal (top and bottom) 1 cable(s) 0.5…2.5 mm² - rigid
Screw clamp terminal (top and bottom) 2 cable(s) 1.5 mm² - flexible
Screw clamp terminal (top and bottom) 2 cable(s) 1.5 mm² - flexible with ferrule
Wire stripping length9 mm
Tightening torque1 N.m top and bottom
Environment
IP degree of protectionIP20
Pollution degree3
Tropicalisation2
Ambient air temperature for operation-25…50 °C
Ambient air temperature for storage-40…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.800 cm
Package 1 Width7.500 cm
Package 1 Length9.200 cm
Package 1 Weight45.000 g
Unit Type of Package 2BB1
Number of Units in Package 212
Package 2 Height8.500 cm
Package 2 Width10.000 cm
Package 2 Length23.500 cm
Package 2 Weight588.000 g
Unit Type of Package 3S03
Number of Units in Package 3108
Package 3 Height30.000 cm
Package 3 Width30.000 cm
Package 3 Length40.000 cm
Package 3 Weight5.915 kg
arrow2_down
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Materials and Substances
Use Again
Repack and remanufacture
Documents
arrow2_down
Software and Firmware
arrow2_down
arrow2_down

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.

  • Products Documentation
  • Software Downloads
  • Product Substitution and Replacement
  • Help and Contact Center
  • Find our Offices
  • Where to buy
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings