Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
0
EasyLogic PM2130, Power & Energy meter, up to the 31st harmonic, LED display, RS485, class 0.5S

METSEPM2130

Display type:

[Us] rated supply voltage:

Bill checking to verify that you are only charged for the energy you use
Aggregation of energy consumption and cost allocation within the same facility
Energy cost and usage analysis to optimise energy usage
Metering of electrical parameters to understand your electrical distribution system
Environmental Data
Total lifecycle Carbon footprint
157
Use Better
Packaging made with recycled cardboard
information_stroke
Recycled cardboard content is minimum 70% (50% in US). Some orders may include non-recycled cardboard until stock runs out.
Yes
Use Again
Recyclability potential, in %
information_stroke
The calculation of the recyclability potential relies on the scenario "France - parts are shredded" of TR62635 considering all parts in the product and materials recyclability. We recognized that this may not always allow comparison with other competitor offers on the market and are waiting for a common standard to be published end of 2026.
9
Take-back
information_stroke
Whether the product has been included in a global take-back program. Some products are eligible in some geographies, please verify if it's available in your country.
No
Description
arrow2_down
This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having 3 rows of bright red 4 digits 14.2 mm height LED display. The meter measures active energy as per accuracy class Class 0.5S complying to IEC 62053-22 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion and Individual harmonics up to 31st Harmonic order. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 80 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. It is having RS485 communication port over Modbus RTU protocol. The meter can be upgraded with optional add on IO modules for WAGES monitoring. These module comes with either two channels each of digital inputs and outputs or analog inputs and outputs. This version can be configured for 23 different types of alarms stored in 40 registers. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).
Specifications
arrow2_down
Main
RangeEasyLogic
Product nameEasyLogic PM2100
Product or component typePower meter
Device short namePM2130
Complementary
Device applicationSub billing
Power monitoring
Power quality analysistotal harmonic distortion
up to the 31st harmonic
Type of measurementApparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy total
Metering typePeak demand currents
Active power P, P1, P2, P3
Demand power P, Q, S
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Active, reactive, apparent energy (signed, four quadrant)
Voltage U, U21, U32, U13, V, V1, V2, V3
Current I, I1, I2, I3
Calculated neutral current
Unbalance current
Peak demand power PM, QM, SM
Accuracy classClass 1 reactive energy conforming to IEC 62053-24
Class 0.5S active energy conforming to IEC 62053-22
Class 5 harmonic distortion (I THD & U THD)
Measurement accuracyApparent power +/- 0.5 %
Active energy +/- 0.5 %
Reactive energy +/- 1 %
Active power +/- 0.5 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current5…6000 mA
Measurement voltage35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range45…65 Hz
[Us] rated supply voltage80...277 V AC 45...65 Hz +/- 10 %
100...277 V DC +/- 10 %
Network frequency50 Hz
60 Hz
Ride-through time50 ms 120 V AC typical
50 ms 230 V AC typical
50 ms 125 V DC typical
[In] rated current1 A
5 A
Maximum power consumption in VA8 VA at 277 V AC
Maximum power consumption in W3.3 W (power lines (AC))
3.3 W at 277 V (power lines (DC))
input impedanceCurrent (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settingsProtected by access code
Display type7 segments LED
Display colourRed
Messages display capacity3 fields of 4 characters
Display digits12 digit(s) - 14.2 mm in height
Demand intervalsConfigurable from 1 to 60 min
Information displayedDemand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Control type3 x button
Local signallingRed LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communication
Number of inputs0
Number of outputs0
Communication port protocolModbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Communication port supportScrew terminal block: RS485
Data recordingPower logs
Time stamping
Energy consumption logs
Min/max for 8 parameters
Function availableReal time clock
Sampling rate64 samples/cycle
CybersecurityEnable/disable communication ports
Communication serviceRemote monitoring
Product certificationsCE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick
Mounting modeClip-on
Mounting positionVertical
Mounting supportFramework
Provided equipment1 x installation guide
Measurement categoryCategory III 480 V
Category II 480…600 V
Electrical insulation classClass II
Double insulation
Flame retardanceV-0 conforming to UL 94
Connections - terminalsCurrent transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4
MaterialPolycarbonate
Width96 mm
DepthTotal : 76.09 mm
Embedded : 61.64 mm
Height96 mm
Net weight300 g
Compatibility codePM2130
Environment
service life7 year(s)
IP degree of protectionIP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity5…95 % at 50 °C
Pollution degree2
Ambient air temperature for operation-10…60 °C
Ambient air temperature for storage-25…70 °C
Operating altitude<= 2000 m
Electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class A
Overvoltage categoryIII
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.500 cm
Package 1 Width12.000 cm
Package 1 Length12.500 cm
Package 1 Weight407.000 g
Unit Type of Package 2S03
Number of Units in Package 218
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.726 kg
Unit Type of Package 3P06
Number of Units in Package 3144
Package 3 Height7.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight71.808 kg
arrow2_down
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Materials and Substances
Use Again
Repack and remanufacture
Documents
arrow2_down
Software and Firmware
arrow2_down
arrow2_down

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.

  • Products Documentation
  • Software Downloads
  • Product Substitution and Replacement
  • Help and Contact Center
  • Find our Offices
  • Where to buy
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings