Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
0
power meter PowerLogic PM5560, 2 ethernet, up to 63th Harmonic, 1,1MB 4DI/2DO 52 alarms

METSEPM5560

Feature-rich power and energy meters
Digital input and output for WAGES monitoring and control relays
Modbus RS-485, TCP/ IP, Ethernet IP, BACnet protocols for varied application
Identify energy savings opportunties with precision accuracy of Class 0.2S
63rd Hamronic measurement for Power Quality management
Environmental Data
Total lifecycle Carbon footprint
328
Use Better
Packaging made with recycled cardboard
information_stroke
Recycled cardboard content is minimum 70% (50% in US). Some orders may include non-recycled cardboard until stock runs out.
No
Use Again
Take-back
information_stroke
Whether the product has been included in a global take-back program. Some products are eligible in some geographies, please verify if it's available in your country.
No
Description
arrow2_down
This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.2S accuracy per IEC 62053-22 standard and 128 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 63rd Harmonic. Include 1.1 MegaBytes of memory for up to 14 selectable parameters with configurable interval and duration. This meter also feature the direct monitoring of neutral current. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 480 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20 to 690 VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 45 to 65 Hz. Communication protocol are Modbus RTU and ASCII 2 wires with RS485 port support plus Modbus TCP/IP, Ethernet/IP and BACnet/IP based on 10/100 Mbit/s, daisy chain Ethernet with RJ45 port support. The embedded communication capabilities allow the support of the DNP 3.0 protocol, the access to an onboard web server and a Serial to Ethernet gateway. The meter also has four digital inputs with WAGES support and two digital outputs. There are 52 configurable alarms and it supports eight tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 3.03 inches (77 millimetres), height 3.78 inches (96 millimetres) and product weight 15.9 onces (450 g).
Specifications
arrow2_down
Main
RangePowerLogic
Product namePowerLogic PM5000
Device short namePM5560
Product or component typePower meter
Complementary
Power quality analysisup to the 63rd harmonic
Metering typeMeasured neutral current
Calculated ground current
Device applicationGateway
WAGES metering
Power monitoring
Multi-tariff
Type of measurementCurrent
Voltage
Frequency
Power factor
Energy
Active and reactive power
supply voltage100...300 V DC
90...528 V AC 45...65 Hz
Network frequency60 Hz
50 Hz
[In] rated current1 A
5 A
type of network3P + N
3P
1P + N
Maximum power consumption in VA16 VA at 480 V
Ride-through time35 ms 120 V AC typical
129 ms 230 V AC typical
50 ms 125 V DC typical
Display typeBacklit LCD
Display resolution128 x 128 pixels
Sampling rate128 samples/cycle
Measurement current50…10000 mA
Analogue input typeVoltage (impedance 5 MOhm)
Current (impedance <= 0.3 mOhm)
Measurement voltage20…400 V AC 45...65 Hz between phase and neutral
20…828 V AC 45...65 Hz between phases
Frequency measurement range45…65 Hz
Number of inputs4 digital
Measurement accuracyApparent power +/- 0.5 %
Frequency +/- 0.05 %
Active energy +/- 0.2 %
Reactive energy +/- 1 %
Active power +/- 0.2 %
Voltage +/- 0.1 %
Power factor +/- 0.005
Current +/- 0.15 %
Reactive power +/- 1 %
Accuracy classClass 0.2S active energy conforming to IEC 62053-22
Number of outputs2 digital
Information displayedTariff (8)
Communication port protocolModbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V
JBUS
Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V
Ethernet Modbus TCP/IP daisy chain
BACnet IP
DNP3 over ethernet
Communication port supportRS485
ETHERNET
Communication gatewayEthernet/serial
Data recordingEvent logs
Maintenance logs
Min/max of instantaneous values
Data logs
Alarm logs
Time stamping
Memory capacity1.1 MB
Web servicesAlarm notification by e-mail
Diagnostic via predefined web pages
Web server
Real time viewing of data
Ethernet serviceSNTP client
SNMP-Traps
Connections - terminalsVoltage circuit: screw terminal block4
Control circuit: screw terminal block2
Current transformer: screw terminal block6
RS485 link: screw terminal block4
Digital input: screw terminal block8
Digital output: screw terminal block4
Ethernet network: RJ45 connector2
Mounting modeFlush-mounted
Mounting supportFramework
StandardsEN 50470-3
IEC 61557-12:2015
IEC 62053-22:2020
IEC 62053-24
IEC 60529
EN 50470-1
UL 61010-1
ANSI C12.20
IEC 62053-23:2020
IEC 62052-11:2020
IEC 62052-31:2015
Product certificationsCE conforming to IEC 61010-1
CULus conforming to UL 61010-1
BTL
Width96 mm
Depth72 mm
Height96 mm
Net weight450 g
Environment
Electromagnetic compatibilityLimits for harmonic current emissions class A conforming to IEC 61000-3-2
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
Magnetic field at power frequency level 4 conforming to IEC 61000-4-8
Conducted and radiated emissions class B conforming to EN 55022
Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3
Electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Surge immunity test level 4 conforming to IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
IP degree of protectionIP54 display: conforming to IEC 60529
IP30 rear: conforming to IEC 60529
Relative humidity5…95 % at 50 °C non-condensing
Pollution degree2
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Operating altitude<= 3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.000 cm
Package 1 Width12.600 cm
Package 1 Length12.600 cm
Package 1 Weight598.000 g
Unit Type of Package 2S03
Number of Units in Package 212
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.900 kg
Unit Type of Package 3P06
Number of Units in Package 396
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight77.372 kg
arrow2_down
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Materials and Substances
Use Again
Repack and remanufacture
Documents
arrow2_down
Software and Firmware
arrow2_down
arrow2_down

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.

  • Products Documentation
  • Software Downloads
  • Product Substitution and Replacement
  • Help and Contact Center
  • Find our Offices
  • Where to buy
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings