Roll over image to zoom in


2 videos
PAS600
Compact data concentrator for integration of wireless smart IoT, and Modbus devices in energy monitoring systems
Easy configuration and maintenance through user friendly embedded webpages
Seamless commissioning with EcoStruxure Power Commission reports and configuration exports
Operation efficiency for energy data transfer to local scada or cloud application
Enhanced cybersecurity with IEC 62443-4-1 Secure Development Lifecycle
Environmental Data
Total lifecycle Carbon footprint
47
Use Better
Packaging made with recycled cardboard
Yes
Use Again
Take-back
No
EcoStruxure Panel Server is a gateway, providing connection of wired or wireless smart IoT devices to edge control software or cloud application. Connect wireless devices from Schneider Electric such as PowerTag Energy, PowerLogic HeatTag, Power Tag Ambiant, Power Tag control and others. Connect most of Modbus/RS485 and Modbus/TCP devices from the market including Power Meters and Protection devices from Schneider-Electric and third party. User friendly web-pages offer first-level of monitoring of measurements of all the connected devices including log of all alarms. Simple troubleshooting of the system through embedded web-pages with advanced diagnostic information and logs. Easy commissioning through embedded web-pages or with EcoStruxure Power Commission that will offer commissioning reports and advanced features. Product dimensions are as follows: width 72 millimeters, depth 70,2 millimeters and height 93 millimeters. From 110 to 277 VAC/DC 50-60Hz 3W/10VA Max Power Supply. -25°C to +70°C Operating temperature. up to 93% relative humidity. Major certifications including CE, UL/CSA, IEC61010, UL61010, IEC62974-1, Marine certification, RCM, EAC and UKCA. The gateway can be DIN rail mounted in a modular enclosure. It has IP20 connectors, IP40 front face nose and IP30 on others faces. Two 10/100 Base-T Ethernet RJ45 connectors. Modbus RS485 open-style connector. One connector for external Wi-Fi network antenna. Direct cellular connection through external LTE router connected through Ethernet or Wi-Fi. Perfect fit for EcoStruxure Edge Software such as Power Monitoring Expert, Power Operations and EcoStruxure Building Operations. Designed for EcoStruxure Cloud Applications such as Facility Expert, Energy Hub, Asset Advisor and Resource Advisor.
Range | EcoStruxure |
---|---|
Product name | Panel Server Universal |
Product or component type | Gateway |
Device short name | PAS600 |
Device application | Gateway |
[Us] rated supply voltage | 110...277 V AC 50/60 Hz 110...277 V DC |
Communication gateway | Ethernet TCP/IP to wireless devices Ethernet/serial |
Product compatibility | Wireless access point |
---|---|
Maximum power consumption in W | HW V2: 3.5 W 110...277 V HW V1: 3 W 110...277 V |
Maximum power consumption in VA | HW V2: 12 VA at 110...277 V HW V1: 10 VA at 110...277 V |
Communication network type | HW V2: Wi-Fi infrastructure5 GHz HW V2: Wi-Fi infrastructure2.4 GHz HW V1: Wi-Fi infrastructure 10/100BASE-T2.4 GHz Ethernet 10/100BASE-T2.4 GHz Wi-Fi access point IEEE 802.15.42.4 GHz Wireless IEEE 802.15.4 even/odd or none parity 1.2...115.2 kbit/s Modbus RTU Modbus RTU client even/odd or none parity 1.2...115.2 kbit/s |
Communication port protocol | Modbus TCP DHCP HTTPS NTP/SNTP IPv4 IPv6 TCP/IP |
Communication port support | 2 RJ45: ETHERNET Screw terminal block: RS485 |
Number of server device(s) | 32 Modbus RTU product(s) 128 Modbus TCP/IP product(s) 40 wireless (IEEE 802.15.4) product(s) - mixed 85 wireless (IEEE 802.15.4) product(s) - depending on configuration |
Number of devices | 64 Modbus TCP/IP |
Memory capacity | HW V2: 32 GB eMMC HW V1: 512 MB NAND |
Number of inputs | 0 |
Connections - terminals | Power supply: screw terminal block (top) 1.5…2.5 mm² cable(s) Communication: screw terminal block (bottom) 0.14…1.5 mm² cable(s) |
Tightening torque | Power supply: 0.6 N.m Communication: 0.25 N.m |
Wire stripping length | Power supply: 7 mm Communication: 7 mm |
Number of connectors | HW V2: 2 screw connector for Wi-Fi and IEEE 802.15.4 HW V1: 1 screw connector for Wi-Fi |
Connector type | HW V2: connector(s)1 x RP-SMA Wi-Fi for antenna bottom HW V2: connector(s)1 x RP-SMA IEEE 802.15.4 for antenna top HW V1: connector(s)1 x RP-SMA Wi-Fi for antenna bottom |
Mounting mode | Clip-on |
Mounting support | DIN rail |
Product certifications | CE cULus CB RCM UKCA FCC IC DNV Marine ANSI RF IACS E10 |
Standards | IEC 61010 IEC 61010-1 IEC 61010-2-201 UL 61010 UL 61010-1 UL 61010-2-201 EN 61010-1 EN 61010-2-201 CAN/CSA C22.2 No. 61010-1-12 CAN/CSA C22.2 No. 61010-2-201 IEC 62974-1 IEC 61326-1 EN 61326-1 ETSI EN 301 489-1 ETSI EN 301 489-17 EN 301-893 EN 55032 CISPR 11 ETSI EN 300 328 IEEE 802.15.4 IEEE 802.11a/b/g/n IEEE 802.3 af/at FCC CFR 47 part 15 class A EN 62311 IEC 62311 ANSI C63.10 IEC 60945 EN 62974-1 DNVGL-GC-0339 |
Depth | 70.2 mm |
Height | 93 mm |
Width | 72 mm |
Net weight | 201 g |
Data recording | Real time data monitoring |
Data buffer for data publication (cloud, SFTP, HTTPS) depending on network | 1 month(s) |
Function available | Embedded web page for configuration and upgrade Diagnosis capabilities Diagnostic report Diagnostics on communication Energy management With integrated web server Firmware update Backup/restore configuration Configurable event |
Product specific application | Wireless Schneider Electric devices ecosystem |
Topology | Separated Ethernet network Switched Ethernet network |
Web services | HTTPS server SFTP publication (CSV / JSON) HTTPS publication (CSV / JSON) |
Communication service | Device Profile for Web Services (DPWS) Modbus TCP client Modbus TCP server SNTP client DHCP client RSTP |
Commissioning interface | EcoStruxure Power Commission desktop EcoStruxure Power Commission Mobile (through Wi-Fi Access point) EcoStruxure Power Commission web (for third party device integration) Web page |
Realtime clock | With RTC-battery set With user calibration |
Time synchronisation protocol | NTP SNTP |
Range compatibility | EcoStruxure Facility Expert EcoStruxure Building Operation EcoStruxure Power Operation EcoStruxure Power Monitoring Expert EcoStruxure Asset Advisor EcoStruxure Energy Hub EcoStruxure Resource Advisor Third party SCADA |
Communication interface | Modbus and wireless (IEEE802.15.4) product |
Relative humidity | 5…95 % |
---|---|
IP degree of protection | IP40 (front face) IP20 (casing) |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -40…85 °C |
Pollution degree | 2 |
Operating altitude | < 2000 m |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 9.000 cm |
Package 1 Width | 9.000 cm |
Package 1 Length | 11.000 cm |
Package 1 Weight | 283.000 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 27 |
Package 2 Height | 30.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 8.280 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 216 |
Package 3 Height | 75.000 cm |
Package 3 Width | 60.000 cm |
Package 3 Length | 80.000 cm |
Package 3 Weight | 74.200 kg |
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Total lifecycle Carbon footprint
47
Environmental Disclosure
Use Better
Packaging made with recycled cardboard
Yes
Packaging without single use plastic
Yes
Compliant with Exemptions
SCIP Number
8fd200e0-fc2c-4c52-ba68-62f2aced16fe
REACh Regulation
Halogen-free status
Halogen free plastic parts & cables product
PVC free
Yes
Use Again
End of life manual availability
Removable battery
No
Take-back
No
WEEE Label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins