Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
0
APC Smart-UPS 5000VA 230V Rackmount/Tower

SUA5000RMI5U

Battery type:

Input voltage:

Replacement battery (1) is available
"Intelligent and efficient network power protection from entry level to scalable runtime. "
"Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices."
"Provides remote management of the UPS over the network."
"LED status indicators Quickly understand unit and power status with visual indicators"
Environmental Data
Total lifecycle Carbon footprint
4487
Use Better
Packaging made with recycled cardboard
information_stroke
Recycled cardboard content is minimum 70% (50% in US). Some orders may include non-recycled cardboard until stock runs out.
Yes
Energy Efficiency Optimized
information_stroke
The energy efficiency of this Product is at least 10% better than market average or product previous generation.
Energy efficient product
Use Again
Take-back
information_stroke
Whether the product has been included in a global take-back program. Some products are eligible in some geographies, please verify if it's available in your country.
Yes
arrow2_down
+ Lifecycle Services
1 Yr Advantage EAA Prevent Service Plan for (1) 1P UPS up to 10kVA

WADV1PEAA

Scheduled 5X8 assembly service and Power-Up service

WASSEMUPS-3R-SB-00

Description
arrow2_down
Intelligent and efficient network power protection from entry level to scalable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
Specifications
arrow2_down
Overview
PresentationIntelligent and efficient network power protection from entry level to scalable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
Lead timeUsually Ships within 4 Weeks
Main
Run time for load
W
information_stroke
Enter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.
Min-max: 400-4000 W
9min 21s
Max. Capacity Used
information_stroke
The maximum percentage of UPS capacity used to support your specified load.
100 %
Product or component typeUninterruptible power supply (UPS)
Complementary
Communication port typeSmartSlot
Batteries & Runtime
Run TimeView Runtime Graph
Battery typeLead-acid battery
Additional informationConfigurable for 220 : 230 or 240 nominal output voltage
Extended runtime0
Number of battery filled slots0
Number of battery free slots0
Battery recharge time3 h
Number of battery replacement quantity2
Battery life3…5 year(s)
Replacement batteryRBC55
Battery charger power542 W rated
General
Provided equipmentCD with software
Documentation CD
Installation guide
Rack mounting hardware
Rack mounting support rails
Smart UPS signalling RS-232 cable
User manual
Web/SNMP management card
Number of power module0
Number of power module filled slots0
Number of power module free slots0
RedundantNo
Physical
Number of rack unit5U
ColourBlack
Height22.2 cm
Width48.3 cm
Depth66 cm
Net weight97.73 kg
Mounting locationFront
Mounting preferenceNo preference
Mounting modeRack-mounted
Two post mountable0
USB compatibleNo
Input
Main Input Voltage230 V
Input voltage limits151...302 V adjustable
160...286 V
Number of input connectors1 hard wire 3-wire
Network frequency50/60 Hz +/- 3 Hz auto-sensing
Output
Main Output Voltage230 V
Other Output Voltage220 V
240 V
Rated power in W4000 W
Rated power in VA5000 VA
output connection type8 IEC 320 C13
4 IEC Jumpers
2 IEC 320 C19
Crest factor3 : 1
Harmonic distortionLess than 5 % at full load
Maximum configurable power in VA5000 VA
Maximum configurable power in W4000 W
Transfer time2 ms typical : 4 ms maximum
UPS typeLine interactive
Wave typeSine wave
Efficiency96 % (full load)
Output frequency47...53 Hz for 50 Hz nominal sync to mains
Conformance
Product certificationsC-Tick
CE
GOST
VDE
MarkingGS Mark
StandardsEN/IEC 62040-1:2019/A11:2021
EN/IEC 62040-2:2006/AC:2006
EN/IEC 62040-2:2018
Environmental
Acoustic level53 dBA
Heat dissipation430 Btu/h
Operating altitude0...10000 ft
Ambient air temperature for operation0…40 °C
Ambient air temperature for storage-15…45 °C
Storage altitude0…15240 m
Relative humidity0…95 %
Storage Relative Humidity0…95 %
Communications & Management
AlarmAudible and visible alarms : configurable delays
Free slots0
Preinstalled deviceNetwork management card
Control panelLED status display with on line : on battery : replace battery and overload indicators
Surge Protection and Filtering
Surge energy rate480 J
Noise suppressionFull time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height63.5 cm
Package 1 Width61 cm
Package 1 Length76.2 cm
Package 1 Weight106.82 kg
Unit Type of Package 2PAL
Number of Units in Package 24
Package 2 Height119 cm
Package 2 Width100 cm
Package 2 Length120 cm
Package 2 Weight464 kg
Contractual warranty
Warranty2 years repair or replace
arrow2_down
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Materials and Substances
Energy efficiency
Use Again
Repack and remanufacture
Documents
arrow2_down
Software and Firmware
arrow2_down

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.

  • Products Documentation
  • Software Downloads
  • Product Substitution and Replacement
  • Help and Contact Center
  • Find our Offices
  • Where to buy
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings