How can we help you today?

Which power phases are controlled by Altistart 01 Soft-Starter?

The power phases that are controlled by the Altistart 01 Soft-Starter are as follows:

In the N1 Range of Altistart 01 Soft-Starter, for ATS01N103FT and ATS01N106FT, only 1 phase is controlled, and that is L3. L1 and L2 are uncontrolled.

In the N1 Range of Altistart 01 Soft-Starter, from ATS01N109FT to ATS01N125FT, only 1 phase is controlled, and that is L1. L2 and L3 are uncontrolled.

In the N2 Range of Altistart 01 Soft-Starter, 2 phases are controlled, and those are L1 and L2. L3 is uncontrolled.