How can we help you today?

How do I reset the configuration and password of an MCSESM Modicon switch to factory settings?

Issue

The password of an MCSESM Modicon switch is no longer available, and the switch needs to be reset to factory settings.

Important: This procedure clears the switch configuration and boot parameters. The existing configuration will be lost.

Product Line

  • MCSESM Modicon switch products
  • Modicon Memory Back Up Adaptor, commercial reference MCSEAM0100

Environment

The procedure requires:

  • A Modicon Memory Back Up Adaptor MCSEAM0100
  • A USB Type-C cable
  • A PC
  • A terminal emulator, such as PuTTY

Resolution

1. Start the switch in SysMon1

  1. Power off the switch.
  2. On the PC, create an empty file named recovery.txt on the MCSEAM0100 Modicon Memory Back Up Adaptor.
  3. Safely eject the adaptor from Windows.
  4. Connect the adaptor to the switch.
  5. Power on the switch.
  6. Wait until the status LED starts flashing.
  7. Remove the adaptor.
  8. Connect the PC to the switch using the USB Type-C cable.
  9. Open a terminal session, for example with PuTTY.

The switch should now be in SysMon1.

2. Restore the factory configuration

From the SysMon1 main menu:

  1. Press 4 to select Manage configurations.
  2. Press 1 to execute Clear configuration and boot param.
  3. Press Enter to load the factory settings.
  4. Press q to return to the main menu.
  5. Press q again to reboot the switch with the factory settings.

After the reboot, the previous configuration has been cleared and the switch uses its factory settings.

Applicable Conditions

Use this procedure only when restoring the switch to its factory configuration is acceptable. Any existing configuration will be lost.

Schneider Electric Malaysia

Explore more
Product:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Product:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Centre
  • Find our Offices
  • Get a Quote
  • Where to buy
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings