Examples of alarms reported:
"Device UPS: Return from bypass, internal hardware fault no longer present. 0x01B2"
"Device UPS: In bypass in response to an internal hardware fault. 0x011B"
Product Line: Smart-UPS with Network Management Card (NMC) 3
Environment: Network Management Card firmware version 2.2.0.1
Resolution: This issue has been addressed in NMC3 firmware version 2.2.1.1. Please update the firmware of your NMC3 to the latest version.
The latest NMC3 firmware is available on apc.com. Refer to the below example on how to find and download the NMC3 firmware, and to FA156047 for instructions on upgrading the NMC3 firmware.
Released for: Schneider Electric Malaysia
Examples of alarms reported:
"Device UPS: Return from bypass, internal hardware fault no longer present. 0x01B2"
"Device UPS: In bypass in response to an internal hardware fault. 0x011B"
Product Line: Smart-UPS with Network Management Card (NMC) 3
Environment: Network Management Card firmware version 2.2.0.1
Resolution: This issue has been addressed in NMC3 firmware version 2.2.1.1. Please update the firmware of your NMC3 to the latest version.
The latest NMC3 firmware is available on apc.com. Refer to the below example on how to find and download the NMC3 firmware, and to FA156047 for instructions on upgrading the NMC3 firmware.
Released for: Schneider Electric Malaysia








Need help?
Start here!
Find answers now. Search for a solution on your own, or connect with one of our experts.
Contact Support
Reach out to our customer care team to receive more information, technical support, assistance with complaints and more.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Search FAQs
Search topic-related frequently asked questions to find answers you need.
Contact Sales
Start your sales enquiry online and an expert will connect with you.