Malaysia
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

PM5561 powermeter w 1mod2eth - upto 63th H - 1,1M 4DI/2DO 52alarms - flush MID

Show more characteristics >
  • Training Objectives
    Compliant
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    PowerLogic
    product name
    PowerLogic PM5000
    device short name
    PM5561
    product or component type
    Power meter
    Complementary
    power quality analysis
    up to the 63rd harmonic
    metering type
    Measured neutral current
    Calculated ground current
    device application
    Multi-tariff
    WAGES metering
    Gateway
    Power monitoring
    type of measurement
    Current
    Voltage
    Frequency
    Power factor
    Energy
    Active and reactive power
    supply voltage
    125...250 V DC
    100...480 V AC 45...65 Hz
    network frequency
    60 Hz
    50 Hz
    [In] rated current
    5 A
    1 A
    type of network
    3P
    3P + N
    1P + N
    ride-through time
    35 ms 120 V AC typical
    129 ms 230 V AC typical
    display type
    Backlit LCD
    display resolution
    128 x 128 pixels
    sampling rate
    128 samples/cycle
    measurement current
    5…10000 mA
    analogue input type
    Voltage (impedance 5 MOhm)
    Current (impedance 0.3 MOhm)
    measurement voltage
    20…400 V AC 45...65 Hz between phase and neutral
    20…690 V AC 45...65 Hz between phases
    frequency measurement range
    45…65 Hz
    number of inputs
    4 digital
    measurement accuracy
    Apparent power +/- 0.5 %
    Frequency +/- 0.05 %
    Active energy +/- 0.2 %
    Reactive energy +/- 1 %
    Active power +/- 0.2 %
    Voltage +/- 0.1 %
    Power factor +/- 0.05 %
    Current +/- 0.15 °C
    accuracy class
    Class 0.2S active energy conforming to IEC 62053-22
    number of outputs
    2 digital
    information displayed
    Tariff (8)
    communication port protocol
    Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V
    JBUS
    Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V
    Ethernet Modbus TCP/IP daisy chain
    communication port support
    RS485
    Ethernet
    communication gateway
    Ethernet/serial
    data recording
    Maintenance logs
    Data logs
    Alarm logs
    Event logs
    Min/max of instantaneous values
    Time stamping
    memory capacity
    1.1 MB
    web services
    Alarm notification by e-mail
    Web server
    Diagnostic via predefined web pages
    Real time viewing of data
    Ethernet service
    SNMP-Traps
    SNTP client
    connections - terminals
    Voltage circuit: screw terminal block4
    Control circuit: screw terminal block2
    Current transformer: screw terminal block6
    RS485 link: screw terminal block4
    Digital input: screw terminal block8
    Digital output: screw terminal block4
    Ethernet network: RJ45 connector2
    mounting mode
    Flush-mounted
    mounting support
    Framework
    standards
    IEC 60529
    EN 50470-1
    UL 61010-1
    IEC 62053-24
    EN 50470-3
    IEC 62053-22
    IEC 61557-12
    ANSI C12.20
    product certifications
    CE conforming to IEC 61010-1
    CULus conforming to UL 61010-1
    MID conforming to EN 50470-1
    MID conforming to EN 50470-3
    width
    96 mm
    depth
    72 mm
    height
    96 mm
    net weight
    450 g
    Environment
    electromagnetic compatibility
    Limits for harmonic current emissionsclass A conforming to IEC 61000-3-2
    Conducted RF disturbanceslevel 3 conforming to IEC 61000-4-6
    Magnetic field at power frequencylevel 4 conforming to IEC 61000-4-8
    Conducted and radiated emissionsclass B conforming to EN 55022
    Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3
    Electrostatic discharge - test level: 8 kVlevel 4 conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity testlevel 4 conforming to IEC 61000-4-4
    Surge immunity testlevel 4 conforming to IEC 61000-4-5
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    IP degree of protection
    Front: IP52 conforming to IEC 60529
    Body: IP30 conforming to IEC 60529
    relative humidity
    5…95 % at 50 °C
    pollution degree
    2
    ambient air temperature for operation
    -25…70 °C
    ambient air temperature for storage
    -40…85 °C
    operating altitude
    3000 m
    compatibility code
    PM5561
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • German
    • Chinese
    Catalogue
    Date
    Size
    Add to My Documents
    PowerLogic Catalog - 272 pages Web (NO PRINTED VERSION AVAILABLE) (Version 8.2)
    Catalogue for Panel Builders - Web Version (Version 3.0)
    Catalogue for Panel Builders - Print Version (Version 3.0)
    PowerLogic Catalogue - 272 pages - Print File (NO PRINTED VERSION AVAILABLE) (Version 8.2)
    User guide
    Date
    Size
    Add to My Documents
    PowerLogic™ PM5500 series user manual (Version 06)
    CAD
    Date
    Size
    Add to My Documents
    CAD files for METSEPM5561: Powerlogic PM5500 (Version 1.0)
    Powerlogic PM5500 (Version 1.0)
    Date 5/28/13
    Size 771.7 KB
    Date 5/28/13
    Size 322.8 KB
    Instruction sheet
    Date
    Size
    Add to My Documents
    PowerLogic PM5561 installation sheet -EN-ES-FR-DE-IT-PT-RU-ZH (Version 02)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    CE mark for PM5000 MID meters (Version 1.0)
    Date 5/6/16
    Size 643.2 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    Power Logic TM PM5500 - EoLi (Version 1.0)
    Date 3/6/14
    Size 1.2 MB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Power Logic TM PM5500 - PEP (Version 1.0)
    Date 3/6/14
    Size 413.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Technical leaflet
    Date
    Size
    Add to My Documents
    PM5000 Technical Datasheet - Web Version (Version 3.4)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /