Is it possible to define the resolution of the PTO (Pulse Train Output) of Lexium 32?
Yes, it is possible to set the pulse output resolution of the PTO output on Lexium 32 C and Lexium 32 M. (Lexium 32 A does not incorporate PTO or PTI) The parameter defines the pulses per revolution of the PTO output of Lexium 32 is the ESIM_scale parameter.
The resolution can be freely scaled from 8 ppr to 65535 ppr. The default pulses per revolution are 4096.
When commisssioning with SoMove this parameter can be found under Parameter List > I/O functions > PTO.