United Kingdom
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all VarPlus Logic
Schneider Eletric VPL06N Picture

VPL06N

Schneider Eletric VPL06N Picture
VPL06N

Power Factor controller - VarPlus Logic - VPL 6

Show more characteristics >
  • RRP
    377.67 GBP
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    VarPlus
    product name
    VarPlus Logic
    device short name
    VPL6
    product or component type
    Power factor controller
    Complementary
    number of step output contacts
    6
    [Us] rated supply voltage
    90...550 V AC
    <= 999 kV AC with external VT
    measurement current
    0…5 A
    measurement voltage
    90…550 V AC 50/60 Hz
    operating mode
    Manual or automatic
    number of quadrant operation for generator application
    4
    device connection
    Communication protocol: Modbus interface: RS485
    input function
    Switch: 1 x dry contact
    colour code
    Front: dark grey RAL 7016
    display type
    Backlit LCD
    display size
    56 x 25 mm
    function available
    Automatic detection
    Advanced programming (expert)
    Manual programming
    Any step sequence
    Automatic initialisation
    metering type
    Power factor and displacement PF (signed, four quadrant)
    Total current harmonic distortion THD (I)
    Power factor average over lifetime
    Temperature maximum
    Phase current I1, I2, I3 RMS on load
    Active power P, P1, P2, P3 on load
    Reactive power Q, Q1, Q2, Q3 on load
    Apparent power S, S1, S2, S3 on load
    Voltage U21, U32, U13, V1, V2, V3 on load
    type of measurement
    Ambient temperature inside the cubicle
    Tan φ
    Individual voltage harmonic
    Cos φ
    Operating time
    Power factor
    Capacitor current overload Irms/I1
    information displayed
    Number of switching cycles per step
    Remaining step capacity in %
    Individual step size in kVAr
    type of alarms
    Step power loss (< 75 %) / Action: message and alarm contact + step blocked
    Step faulty / Action: message and alarm contact + step blocked
    High current (> 6 A CT) / Action: message and alarm contact
    Hunting (unstable regulation) / Action: message and alarm contact + step blocked
    Low current (< 15 mA CT) / Action: message and alarm contact
    Overcompensation / Action: message and alarm contact
    Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off
    Overtemperature (50 °C) / Action: message and alarm contact + step switched off
    Overtemperature (30 °C) / Action: fan switch
    Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
    Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
    data recording
    5 alarms
    Operational Hours alarm
    100000 h without maintenance
    Operational counter alarm
    65000 cycles without maintenance
    input type
    Insensitive to phase rotation polarity
    Insensitive to CT polarity
    Phase to neutral
    Current input CT...X/5 A and X/1 A
    Phase to phase
    output type
    Control relay: 0.2 A 110 V DC
    Control relay: 1 A 48 V DC
    Control relay: 2 A 400 V AC 50/60 Hz
    Control relay: 1 A 24 V DC
    Control relay: 5 A 250 V AC 50/60 Hz
    Control relay: 5 A 120 V AC 50/60 Hz
    Fan: 5 A 250 V AC 50/60 Hz
    Fan: 1 A 48 V DC
    Alarm relay: 5 A 250 V AC 50/60 Hz
    Alarm relay: 1 A 48 V DC
    Maximum at the common terminal
    10 A
    settings operating mode
    Manual
    Automatic
    type of setting
    Choice of stepping programs: auto
    Choice of stepping programs: LIFO
    Choice of stepping programs: linear
    Delay between 2 successive switch on the same step: 5...1200 s
    Step configuration programming: auto
    Step configuration programming: off
    Step configuration programming: fixed
    Target cos phi: 0.7 inductive...0.7 capacitive
    Target cos phi: dual cos φ
    measurement accuracy
    Voltage +/- 1 %
    Current +/- 1 %
    Frequency +/- 1 %
    Energy (P,Q,S) +/- 2 %
    Cos φ +/- 2 %
    Total voltage harmonic distortion THD (U) +/- 2 %
    Individual voltage harmonic +/- 3 %
    Temperature +/- 3 °C
    time delay range
    1...6500 s (on reconnection)
    1...6500 s (on response)
    provided equipment
    User manual
    mounting mode
    Flush-mounted
    mounting support
    Panel - thickness: 1…3 mm
    mounting location
    In cabinet
    cut-out dimensions
    138 x 138 mm
    height
    144 mm
    width
    144 mm
    depth
    58 mm
    net weight
    0.6 kg
    Environment
    standards
    IEC 61000-6-2
    EN 61010-1
    IEC 61000-6-4
    IEC 61326-1
    UL 61010-1
    product certifications
    EAC
    NRTL
    CNRTL
    CE
    IP degree of protection
    Front face: IP41
    Rear face: IP20
    operating altitude
    <= 2000 m
    ambient air temperature for operation
    -20…60 °C
    ambient air temperature for storage
    -40…85 °C
    Offer Sustainability
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • Documents and Downloads

    Language
    • English
    • Slovak
    • Spanish
    • Slovenian
    • French
    • Serbian
    • Chinese
    • Hungarian
    • Norwegian
    • Dutch
    • Turkish
    • Korean
    • Portuguese
    • Russian
    • Greek
    • Czech
    • Croatian
    • Polish
    • Italian
    • Romanian
    • German
    • Swedish
    • Bulgarian
    Catalogue
    Date
    Size
    Add to My Documents
    Power Factor Correction - VarSet - Low Voltage Capacitor Banks - 2018 Catalogue (Version 3.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    VarPlus Logic VL series (VL6, VL12) Power Factor Correction Controller (Version 00)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    VarPlusLogic declaration of conformity (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 16/09/19
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 16/09/19
    Size 195.3 KB
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Date 16/09/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.