United Kingdom
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Harmony-XAC
Schneider Eletric XACB3291 Picture

XACB3291

Schneider Eletric XACB3291 Picture
XACB3291

pendant control station XAC-B - 2 pushbuttons 1 Emergency stop

Show more characteristics
  • RRP
    237.63 GBP
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Harmony XAC
    product or component type
    Pendant control station
    device short name
    XACB
    Complementary
    control station type
    Double insulated
    enclosure material
    Glass reinforced polyester
    electrical circuit type
    Power circuit
    enclosure type
    Complete ready for use
    control station application
    Control of 2-speed hoist motor
    control station composition
    2 push-buttons + 1 emergency stop
    control button type
    Stop push-button Ø 40 mm 3 NC latching
    First push-button 2-pole raise, slow-fast
    Second push-button 2-pole lower, slow-fast
    product compatibility
    XESD1291 for reversing operation
    XACS499 for emergency stop
    mechanical interlocking
    With mechanical interlocking
    control station colour
    Yellow
    connections - terminals
    Screw clamp terminals, 1 x 2.5 mm² with or without cable end
    Screw clamp terminals, 2 x 1.5 mm² with or without cable end
    standards
    EN/IEC 60947-5-1
    EN/IEC 60204-32
    CSA C22.2 No 14
    product certifications
    CSA type 4
    protective treatment
    TH
    ambient air temperature for operation
    -25…70 °C
    ambient air temperature for storage
    -40…70 °C
    vibration resistance
    15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
    shock resistance
    100 gn conforming to IEC 60068-2-27
    overvoltage category
    Class II conforming to IEC 61140
    IP degree of protection
    IP65 conforming to IEC 60529
    mechanical durability
    1000000 cycles
    cable entry
    Rubber sleeve with stepped entry 10…22 mm
    [Ithe] conventional enclosed thermal current
    12 A
    [Ui] rated insulation voltage
    Emergency stop contact: 400 V (pollution degree 3) conforming to IEC 60947-1
    600 V conforming to CSA
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-1
    contact operation
    Snap action
    operating force
    17 N push-button
    40 N emergency stop
    short-circuit protection
    10 A fuse protection by cartridge fuse type aM
    rated power in hp
    2 hp at 240 V, CSA certified
    3 hp at 600 V, CSA certified
    5 hp at 400 V, CSA certified
    rated operational power in W
    2200 W AC-3 at 240 V conforming to IEC 60947-3 appendix A
    2200 W AC-3 at 400 V conforming to IEC 60947-3 appendix A
    2200 W AC-4 at 240 V conforming to IEC 60947-3 appendix A
    2200 W AC-4 at 400 V conforming to IEC 60947-3 appendix A
    electrical durability
    300000 cycles AC-3, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    300000 cycles AC-3, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    300000 cycles AC-4, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    300000 cycles AC-4, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    500000 cycles AC-3, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    500000 cycles AC-4, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    800000 cycles AC-3, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    800000 cycles AC-4, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    terminals description ISO n°1
    (51-52-54)OC
    (61-62-64)OC
    (43-44)NO
    (33-34)NO
    (13-14)NO
    (23-24)NO
    terminals description ISO n°2
    (31-32)NC
    (11-12)NC
    (21-22)NC
    terminal identifier
    (11-12)NC
    (13-14)NO
    net weight
    0.99 kg
    Offer Sustainability
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages6
    • English6
    • French1
    • Kazakh1
    • Russian1
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 10.2 MB
    Date 13/08/19
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Certificate
    Format
    Size
    Date
    Add to My Documents
    XAC, XAL, XAPS, XAW Control Stations (Version 1.0)
    Description
    GOST Certificate
    Size PDF
    Size 897 KB
    Date 06/02/15
    Description
    GOST Certificate
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    pendant control station XAC-B - 2 pushbuttons 1 Emergency stop
    Description
    pendant control station XAC-B - 2 pushbuttons 1 Emergency stop
    Size pdf
    Size 195.3 KB
    Date 20/11/19
    Description
    pendant control station XAC-B - 2 pushbuttons 1 Emergency stop
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    pendant control station XAC-B - 2 pushbuttons 1 Emergency stop
    Description
    pendant control station XAC-B - 2 pushbuttons 1 Emergency stop
    Size pdf
    Size 195.3 KB
    Date 20/11/19
    Description
    pendant control station XAC-B - 2 pushbuttons 1 Emergency stop
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    pendant control station XAC-B - 2 pushbuttons 1 Emergency stop
    Description
    pendant control station XAC-B - 2 pushbuttons 1 Emergency stop
    Size pdf
    Size 195.3 KB
    Date 20/11/19
    Description
    pendant control station XAC-B - 2 pushbuttons 1 Emergency stop
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /